Download Print this page

Da-Lite Designer Da-Tab Electrol Instruction Book page 5

Advertisement

Designer Da-Tab Electrol® Installation
120V Wiring Diagram
External Wiring
To Be Completed
By Installer.
Side View
Of Switch
And Box
NOTE: A single switch cannot be used to operate more than
one screen. Contact the factory for further information.
Screen Adjustment For 120V And 220V/240V Screens
Screen travel is stopped automatically in the down and up positions by the limit switches that are preset at the factory. If it's necessary
to adjust for more or less drop follow the steps below. The case cover must be removed to access the motor limit switches.
Remove the front cover of the screen from the back of the screen. Lift front cover up approximately 1/2" and pull away from back of
screen. See Figure 1.
Setting The Down Limit Position
To Reduce Screen Drop:
Turn the white limit switch screw clockwise to decrease the
amount of screen drop. Run the screen down to test the stop
position. If the screen drops too far, raise the screen about
one foot and adjust the limit switch again. Repeat until the
desired position is set.
To Junction Box, Mounted In Screen Case,
In Which Internal Wiring Terminates In White,
Black And Red Leads.
Rocker
Black
Red
Switch
Up
Off
Down
Black With Yellow
This Switch Cannot Be Used With LVC.
240 Volt Wiring Diagram For Standard Wall Switch:
Da-Lite offers two styles of 240 volt wall switches for standard
operation. Please see wiring diagram included in wall switch box
included with screen.
Down White Limit
Switch Knob
Operating Switch, Switch
Box, And Plate Furnished
With Screen. (SPDT With
Center Off)
AC Common
AC Hot
120 V. 50/60 Hz.
2.5 Amp. Max
To Increase Screen Drop:
Turn the white limit switch screw counterclockwise to
increase the amount of screen drop. Run the screen down to
test the stop position. If the screen does not drop enough,
raise the screen about one foot and adjust the limit switch
again. Repeat until the desired position is set. Do not adjust
for more drop than what was ordered. At least 1-1/2 wraps of
fabric must remain on the roller.
Motor
Up Red Limit Switch Knob
In Multiple Control Installations
This Switch Is Replaced By The
Low Voltage Control, Operated
From Push Button Stations.
Figure 3
5

Advertisement

loading