Force Setting

1. Press and hold [ENTER] for 2 seconds to enter menu selection
2. Using [UP] and [DOWN] to select Force option, and press [ENTER]
3. [INDICATOR] will lit to show current force configuration
4. Using [UP] and [DOWN], to adjust the force in the below manner
6. Press [ENTER] to confirm selection, and a beep will signal for successful setup.

Automatic Closing Setting

1. Press and hold [ENTER] for 2 seconds to enter menu selection
2. Using [UP] and [DOWN] to select Auto option, and press [ENTER]
3. [INDICATOR] will lit to show current configuration
4. Using [UP] and [DOWN], to adjust the automatic closing setting in the below manner
Above shows a setting for 50s automatic closing
5. Press [ENTER] to confirm selection, and a beep will signal for successful setup.
Glidermatic GRD+ Installation Instructions & owner's manual
Increase – Low Sensitivity
Decrease – High Sensitivity
Note: If Auto Close is enabled it is important to fit an
auxiliary safety device like Photo beams to avoid human
entrapment or door accidently hitting any object.
80s
70s
60s
50s
40s
30s
20s
10s
OFF