3.8 Gas Conversion Components
Use the following components to convert from natural gas to propane and vice-versa. See Section
3.6 for orifice quantities required for conversion.
Natural Gas to Propane Components
REF
810-2400
810-2059
New Rating
Contact factory at time of
Label
Burner orifices listed are for fryers operating at altitudes of 610 meters or less. For
†
altitudes greater than 610 meters, contact the factory for the correct orifice size.
3.9 Electrical Connections
Fryers without built-in filtration do not require electrical connection. Fryer systems with built-in
filtration when installed must be electrically grounded in accordance with local codes, or in the
absence of local codes, with the appropriate national standards.
Fryers with built-in filtration systems are equipped with a three-prong (grounding)
plug for protection against shock hazard. It should be plugged directly into a
properly grounded, three-prong receptacle. DO NOT CUT, REMOVE, OR
OTHERWISE BYPASS THE GROUNDING PRONG ON THIS PLUG.
For fryers with built-in filtration systems: The rating plate and wiring diagram are located on the
inside front door panel. Built-in filtration systems are equipped with 120VAC single-phase 60-hertz
system (Domestic), or 230VAC single-phase 50-hertz system (International/CE). Do not cut or
remove the ground prong from the power cord plug.
This appliance requires electrical power (built-in filtration systems only) for
operation. Place the gas control valve in the OFF position in case of a prolonged
power outage. Do not attempt to operate this appliance during a power outage.
DEAN MILLIVOLT GAS FRYERS (CE)
CHAPTER 3: INSTALLATION INSTRUCTIONS
DESCRIPTION
Pilot orifice (LP)
Burner orifice
(diameter: 1.51 mm)
†
conversion. PN 802-2144
Propane To Natural Gas Components
REF
810-0811
810-2060
(diameter: 2.40 mm)
New Rating
Contact factory at time of
Label
conversion. PN 802-2144
WARNING
DANGER
3-13
DESCRIPTION
Pilot orifice (26N)
Burner orifice
†