Table of Contents

Advertisement

3.6 Gas Inputs

Nominal Heat Inputs (Qn), Gas Type, Orifice Size, Part Number and Quantity/Color are listed in the
table below:
MODEL
NOMINAL HEAT
INPUT- Qn
(kW)
SM 80 GM
37.5
SM 60 GM
37.5
SR 52 GM
SM 50 GM
SM 35 GM
SR 38G
SR 42G
SM 20 GM
A. Adjustments for different gases are as follows:
MODEL*
SM 80GM
SM 60GM
*SR prefix- Super Runner Series
*SM prefix- Super Marathon Series
*GM suffix- gas millivolt system with no electrical supply connections required
(1) The Netherlands (NL) only.
DEAN MILLIVOLT GAS FRYERS (CE)
CHAPTER 3: INSTALLATION INSTRUCTIONS
GAS TYPE
G20
G25
G31
G20
G25
G31
G20
30
G25
G31
G20
26
G25
G31
G20
15
G25
G31
ORIFICE
GAS TYPE
SIZE (MM)
2,40
G20
2,40
G25
1,51
G31
2,40(1)
G25(1)
2,40
G20
2,40
G25
1,51
G31
ORIFICE SIZE
ORIFICE
(MM)
PART NO.
2.40
810-2060
2.40
810-2060
1.51
810-2059
2.40
810-2060
2.40
810-2060
1.51
810-2059
2.40
810-2060
2.40
810-2060
1.51
810-2059
2.40
810-2060
2.40
810-2060
1.51
810-2059
2.40
810-2060
2.40
810-2060
1.51
810-2059
GAS PRESSURE AT
REGULATOR
MBAR
INCH W.C.
10,0
4,0
15,0
6,0
27,0
10,8
10,0(1)
4,0(1)
12,0
4,8
17,5
7,0
22,0
8,8
3-9
ORIFICE
QTY/ COLOR
5/BLUE
5/BLUE
5/RED
5/BLUE
5/BLUE
5/RED
4/BLUE
4/BLUE
4/RED
3/BLUE
3/BLUE
3/RED
2/BLUE
2/BLUE
2/RED
BURNER
PILOT
MARKING
MARKING
Blue
26N
Blue
26N
Red
16LP
Blue
26N
Blue
26N
Blue
26N
Red
16LP

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sm40Sm50Sm60Sm80Sm35Sr42 ... Show all