3.7 Gas Conversion: Procedures (cont.)
Manifold Support Bracket
Gas Burner
See Detail A
Orifice
Temperature
Control
Typical gas valve, burner and orifice locations (SM50 shown above).

3.8 Gas Conversion Components

Use the following components to convert from natural gas to propane and vice-versa. See Section
3.6 for orifice quantities required for conversion.
Natural Gas to Propane Kit, 826-1817
Bushing, NPT Flush, SR 42 Series only
Pilot orifice (16LP)
Burner orifice*
(See Table on Page 3-9)
Rating label, contact factory at time of
conversion.
* Burner orifices listed on page 3-9 are for fryers operating at altitudes of 2000 feet or less. For
altitudes greater than 2000 feet, contact the factory for the correct orifice size.
DEAN MILLIVOLT GAS FRYERS (NON-CE)
CHAPTER 3: INSTALLATION INSTRUCTIONS
Vessel Assembly
Pressure
Test
Spigot
Gas
Manifold
Assembly
1/2—3/4 Reducer
Bushing
Gas Valve
1.63-inch [41-mm]
Gas Manifold
Propane To Natural Gas Kit, 826-2017
Bushing, NPT Flush, SR 42 Series only
Pilot orifice (26N)
Burner orifice*
(See Table on Page 3-9)
Rating label, contact factory at time of
conversion.
3-11
Burner
1.30-inch [33-mm]
Orifice
Detail A
Burner/Orifice Location