Rating Plate; Pre-Installation - Dean SM20 Installation & Operation Manual

Gas fryers
Table of Contents

Advertisement

2.4 Rating Plate

Fryers MUST be connected ONLY to the gas-type identified on the attached rating
The rating plate can be found on the inside panel of the fryer door. Information on this plate
includes the model and serial numbers, kW/hr (BTU/hr) of the burners, outlet gas pressure in mbars
(inches W.C.), and configuration: natural or propane gas. Rating plate data is essential for proper
unit identification, communicating with the factory or requesting special parts and/or information.

2.5 Pre-Installation

No structural material on the fryer should be altered or removed to accommodate
placement of the fryer under a hood. Questions? Call the Frymaster/Dean Service
Do not connect this appliance to the gas supply before reviewing all information in
General: Only licensed personnel should install any gas-fired equipment.
A.
1.
A manual gas shut-off valve must be installed in the gas supply line ahead of the fryers for
safety and ease of future service.
2. Dean Super Marathon and Super Runner Series gas fryers operate on millivolt, and do not
require an external electric power supply.
Clearances: The fryer area must be kept free and clear of all combustibles. This unit is design-
B.
certified for the following installations:
1.
Commercial installation only (not for household use).
2.
Non-combustible floor installation equipped with factory-supplied 6-inch (15-cm) adjustable
legs or 5-inch (13-cm) casters;
3. Combustible construction with a minimum clearance of 6-inches (15-cm) side and 6-inches
(15-cm) rear, and equipped with factory-supplied 6-inch (15-cm) adjustable legs or 5-inch
(13-cm) casters.
DEAN MILLIVOLT GAS FRYERS (CE)
CHAPTER 2: IMPORTANT INFORMATION
DANGER
plate.
DANGER
Hotline at 1-800-551-8633.
DANGER
this chapter.
2-3