QUALIFIED
INSTALLER
(381 mm)
Gas line approx. 24" (610 mm)
of flex protruding from
sheet metal box
6' (1,8 m) fan
Gas line
power cord
access
outlet
Valve
Optional
access
fan
panel
X
18
3"
(76 mm)
3"
15"
(76 mm)
4"
(102 mm)
Check that masonry step does not interfere with install dimensions or
vent pipe.
If mantel is combustible, see following section for allowable clearances.
A hearth that is at a height within 4" (102 mm) of the bottom of the heater
MUST be non-combustible.
Minimum width of fi replace opening at front: 33-1/4" (855 mm)
Y
X = 1 5-1/2" (394 mm) minimum
16" (406 mm) if using leveling platform
18-1/2" (470 mm) with fan
Y = 23-1/4" (591 mm)
Dimensions
33" (838 mm)
24" (610 mm)
3"
(76 mm)
(sold separately)
Cavity
6' (1.9 m) Fan power cord
Optional fan
15"
Trim
(381 mm)
10"
(254 mm)
23"
(584 mm)