INLET
3/4" FNPT
CARTRIDGE CHANGE DETERMINATION
• Replace the prefilter cartridge whenever it becomes
excessively dirty (observed visually or by flow restriction).
Follow the change instructions provided with the
cartridge.
• Replace carbon filter cartridges when capacity is
reached or when flow becomes inadequate, but at least
annually. All carbon filter cartridges on multiple cartridge
systems should be changed at the same time. Change
the Everpure SS-10 cartridge when product level in the
cartridge drops below 1/2" from the bottom of the bowl.
• The system pressure gauge or optional Everguard Low
Pressure Alarm (LPA) provides a quick, simple means
of determining when the filter cartridge(s) should be
checked. Installed on the system outlet manifold, the
gauge or LPA can be used to monitor both dynamic
(flowing) and static (line) pressure.
• The cartridge(s) should be changed when the pressure
gauge is in the red area while equipment is in operation,
and yet the needle shows adequate line pressure between
cycles.
• Observe the needle during the next equipment on cycle.
If the needle registers adequate pressure, it can be
assumed that the temporary low-pressure condition
was caused by a brief power failure or other incoming
pressure disruption.
• If the low pressure condition is not due to an external
condition, check/change the prefilter first. If the low
pressure condition is still not corrected, change the
carbon filter cartridges.
34"
OUTLET
3/4" FNPT
ICE MACHINE/
COFFEE
OUTLET
3/4" FNPT
Figure 7 Quad
HIGH FLOW CSR FILTER SYSTEMS INSTALLATION AND OPERATION GUIDE
INLET
3/4" FNPT
25.69"
FLUSHING
For maximum life, all carbon filter cartridges must be
flushed for five (5) minutes at full flow before use.
ALL NEW CARTRIDGES MUST BE FLUSHED AFTER EACH
CARTRIDGE CHANGE BEFORE BEING PUT INTO SERVICE!
If the cartridges are new, have been properly flushed and
both needle and follower register inadequate pressure, or the
LPA is sounding, you may be experiencing inadequate water
pressure or some restriction may exist in the inlet water
line. In either case, the incoming water pressure must be
improved to receive optimum filter life.
COMPLETE CARTRIDGE CHANGE INSTRUCTIONS CAN BE
FOUND ON THE FILTER CARTRIDGE LABEL.
Not for residential use. For food service applications only.

REPLACEMENT PARTS

Contact your local Pentair
cartridges or system replacement parts.
DESCRIPTION
Inlet/Outlet Pressure Gauge
Inlet/Flushing Valve
O-ring for Prefilter or SR-X
Prefilter Bowl
SR-X Bowl
LPA Pressure Switch
Wrench
31.38"
INLET
INSERT TEE FITTING.
3/4" FNPT
ONE OUTLET TO
FOUNTAIN,
ONE OUTLET TO SRX.
OUTLET
3/4" FNPT
Figure 8 Quad Plus
Everpure
dealer for filter
®
®
PART NUMBER
EV3114-09
EV3114-07
EV3112-40
EV3112-38
EV3112-39
EV3016-41
EV3112-41
ICE MACHINE/
COFFEE
OUTLET
3/4" FNPT