• Connect one branch of the service water tee to the
fountain beverage equipment. Connect the other
branch of the tee to the inlet of the SR-X Feeder.
Connect the outlet of the SR-X Feeder to the ice
machine make-up water (not condenser water) line
and coffee brewing equipment.
• The surge tank isolation and flushing valve is located
at the end of the system header. Using fittings and
hose provided, connect one branch of the valve to the
surge/storage tank. Connect a hose from the other
(flushing) branch and run to drain.
NOTE: Some municipal plumbing codes and good
sanitary practices require an air gap at the drain
termination point.
5. The surge/storage tank is pre-pressurized to 20 psi
(1.4 bar). Check pressure and adjust as necessary.
6. Install a manual shut-off valve leading to the system for
servicing and connect minimum 1/2" I.D. (3/4" for quad)
water line to the system inlet.
7. The optional Everguard
consists of a pressure switch, audible/visual alarm box
and a power adapter. It is designed to detect a fixed
low pressure, approx. 20 psi (1.4 bar), condition as an
indication of loss of system outlet pressure either due
to an intentional shut-down or excess fouling of the
water filters, thus indicating the need for filter cartridge
change-out. If the system is equipped with the LPA,
follow these steps:
• Determine location of a convenient 110 VAC outlet to
plug in the LPA power adapter.
• Remove the protective rubber cap from the pressure
switch installed in the system header assembly. Insert
the wires from the LPA unit through the cap and
connect them to the terminals on the pressure switch.
Either wire can be connected to either terminal.
Replace the cap.
• Plug the LPA power adapter into an outlet. The audible
alarm should activate. Push the reset switch
to silence.
• Unplug the LPA unit.
DIMENSIONS
INLET
3/4" FNPT
Figure 5 Twin
2
HIGH FLOW CSR FILTER SYSTEMS INSTALLATION AND OPERATION GUIDE
Low Pressure Alarm (LPA)
TM
25.80"
FOUNTAIN
OUTLET
3/4" FNPT
ICE MACHINE/
COFFEE
OUTLET
3/4" FNPT
8. Shut off the system inlet valve located on the inlet of the
prefilter head.
9. Check to be sure the o-ring on the prefilter housing
is sufficiently lubricated. Use a good grade of silicone
lubricant, if needed. Position the Everpure EC210
prefilter cartridge on guide seat in the bottom of the
bowl. Then thread the bowl into the head by hand. Use a
sump wrench to snug the bowl onto the head.
10. Install only genuine Everpure carbon filter cartridge(s)
into the filter head(s) following directions on the
cartridge label or as shown in the Cartridge Change
illustrations. Install the Everpure
cartridge into the Everpure SR-X housing.
11. Turn on inlet water to the filter system and check
for leaks.
12. Open the flushing valve and flush the cartridge(s) by
running water through at full force for five (5) minutes.
This will set the filtering media and purge any air and
fines, insuring maximum filter life. See illustrations.
13. After flushing, close the flushing valve, turn on power
to equipment and plug the LPA (if so equipped) into the
electrical outlet. The system is ready for operation.
Check for compliance with state and local laws and regula-
tions. Do not use with water that is microbiologically unsafe
or of unknown quality without adequate disinfection before or
after the system. Systems certified for cyst reduction may be
used on disinfected waters that may contain filterable cysts.
For installations in Massachusetts, the Commonwealth of
Massachusetts Plumbing Code 248 CMR shall be adhered to.
Consult your licensed plumber for installation of the system.
This system and its installation must comply with state and
local regulations.
INLET
3/4" FNPT
25.59"
SS-10 Scale Inhibitor
®
30"
FOUNTAIN
OUTLET
3/4" FNPT
Figure 6 Triple
ICE MACHINE/
COFFEE
OUTLET
3/4" FNPT
25.59"