2.1
UNPACKING THE FIRE
Carefully lift the fire out of the carton. Remove the loose item packaging carefully
from the front of the appliance. Check the contents as listed :-
Packing Check List
1 off
Fire box / burner assembly
1 off
Cast trim
1off
Fret / Ashpan
1 off
Boxed ceramic base, 2 piece ceramic front rail 11 synthetic coals
1 off each User instruction book and Installation book
1 off
Flue restrictor baffle (for use in brick built chimneys and large diameter
e.g. 175mm flue applications).
Fixing Kit Check List
2 off
Fixing cables
4 off
Wallplugs
4 off
Eyebolts
2 off
Tensioner bolts & nuts
2 off
Tensioner screws
4 off
Cast trim brackets & screws
2.2
INSTALLING THE FIRE BOX
Establish which type of flue you are intending to install the fire in to :-
225 x 225mm (9 inch x 9 inch) brick built chimneys
175mm (7 inch) diameter lined brick or stone flue, or insulated pre-fabricated
metal flue box to B.S. 715.
When installing into 125mm (5 inch) diameter lined brick or stone flue, or
insulated pre-fabricated metal flue box to B.S. 715 and pre-cast flues the
restrictor baffle must not be fitted.
A spillage test must always be carried out to check satisfactory
clearance of flue products, regardless of the type of flue the
appliance is being fitted to.
SECTION 2
INSTALLATION OF FIRE
10