Flavel Caress Installation And Maintenance Instructions Manual page 18

Coal effect gas fire
Table of Contents

Advertisement

2.3
GAS TIGHTNESS AND INLET PRESSURE
a)
Remove the pressure test point screw from the inlet elbow pressure test
point and fit a manometer.
b)
Turn on the main gas supply and carry out a gas tightness test.
c)
Depress the control lever to the position marked pilot. Hold down the
control lever for a few seconds to purge the pipe work. The burner
should light, continue to hold the control lever for a few seconds to latch
the slide valve then lift to the full-on position.
d)
Check that the gas pressure is 20.0 mbar (+/- 1.0mbar) 8.0 in w.g.(+/-
0.4 in w.g.)
e)
Turn off the fire, remove the manometer and refit the pressure test point
screw. Check the pressure test point screw for gas tightness with the
appliance turned on using a suitable leak detection fluid or detector.
18