To ensure that the release of fibres from these R.C.F (Refractory Ceramic
Fibre) articles is kept to a minimum, during installation and servicing we
recommend that you use a HEPA filtered vacuum to remove any dust
accumulated in and around the appliance before and after working on the
appliance. When replacing these articles we recommend that the replaced
items are not broken up, but are sealed within heavy duty polythene bags,
clearly labelled as "RCF waste". RCF waste is classed as a "stable", non
reactive hazardous waste and may be disposed of at a landfill licensed to
accept such waste Protective clothing is not required when handling these
articles, but we recommend you follow the normal hygiene rules of not
smoking, eating or drinking in the work area, and always wash your hands
before eating or drinking.
3.3
FITTING THE TRIM - CARESS MODELS ONLY
a)
Fit the 4 off mounting brackets supplied with the fire in the loose items
pack to the rear face of the Cast-Iron Trim as shown below in Fig. 19
Fig. 19
23
4 off Mounting
Brackets