call the fire department
4. This fireplace shall not be installed in a
bedroom or bathroom.
5. Do not use this fireplace as a wood-burn-
ing fireplace. Use only the logs provided
with the fireplace.
6. Do not add extra logs or ornaments such
as pine cones, vermiculite, or rock wool.
Using these added items can cause soot-
ing. Do not add lava rock around base.
Rock and debris could fall into the control
area of fireplace.
7. This fireplace is designed to be smoke-
less. If logs ever appear to smoke, turn
off fireplace and call a qualified service
person.
Note: During initial operation, slight smok-
ing could occur due to log curing and
fireplace burning manufacturing residues.
8. To prevent the creation of soot, follow the
instructions in Cleaning and Maintenance,
page 23.
9. Before using furniture polish, wax, carpet
cleaner, or similar products, turn heater
off. If heated, the vapors from these prod-
ucts may create a white powder residue
within burner box or on adjacent walls or
furniture.
10. This fireplace needs fresh air ventilation to
run properly. This fireplace has an Oxygen
Depletion Sensing (ODS) safety shutoff
system. The ODS shuts down the fire-
place if not enough fresh air is available.
Log Set
Remote
Control
Figure 1 - Log Base Assembly
4
SAFETY
Continued

PRODUCT IDENTIFICATION

Base
Front
Assembly
Burner
www.SuperiorFireplaces.US.com
See Air for Combustion and Ventilation,
page 6. If fireplace keeps shutting off, see
Troubleshooting, page 24.
11. Do not run fireplace
• where flammable liquids or vapors are
used or stored.
• under dusty conditions.
12. Do not use this fireplace to cook food or
burn paper or other objects.
13. Do not use fireplace if any part has been
under water. Immediately call a qualified
service technician to inspect the room
fireplace and to replace any part of the
control system and any gas control which
has been under water.
14. Turn off and unplug fireplace and let
cool before servicing. Only a qualified
service person should service and repair
fireplace.
15. Operating fireplace above elevations of
4,500 feet could cause pilot outage.
16. Do not operate fireplace if any log is
broken. Do not operate fireplace if a log
is chipped (dime-sized or larger).
17. To prevent performance problems, do not
use propane/LP fuel tank of less than 100
lbs. capacity (propane/LP only).
18. Provide adequate clearances around air
openings.
19. The screen or any other part removed
for servicing must be replaced prior to
operating this heater.
Left Side
Top panel
Assembly
Fireplace
Hood
Magnet
Screen
Assembly
Figure 2 - Fireplace
Top Outer Casing
Bottom Panel
Assembly
Front
126867-01A
Right
Side

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vrt4032zepVrt4036zenVrt4036ze

Table of Contents