2. Touch the UP or DOWN Buttons to adjust
the day of week (press the MODE/SET
Button or wait for 15 seconds for adjust-
ment to be accepted, then enter hour of
day adjustment).
3. Press the UP or DOWN Buttons to
adjust the hour of the day. The time will
advance in 1-hour increments; AM and
PM will change when the hour advances
to 12:00 midnight and 12:00 noon re-
spectively (press the MODE/SET Button
or wait for 15 seconds for adjustment to
be accepted, then enter minute of hour
adjustment).
4. Press the UP or DOWN Buttons to ad-
just the minute of the hour. The time will
advance in 1-minute increments (press
the MODE/SET Button or wait for 15
seconds and the transmitter will exit
Day/Time Setup and return to normal
operation).
5. LCD Displays – when in Day/Time
Setup:
• MODE Zone: Blank
• ROOM TEMP Zone: Blank
• SET TEMP Zone: Bank
• TIME/PROG Zone: Day of Week, or
Time of Day will Flash
• FLAME Zone: Blank
Program Operation
Touch the TIME/PROG Zone to activate
or deactivate Program Operation. Touch-
ing the MODE Zone or pressing the
MODE/SET Button will also deactivate
Program Operation. When Program Op-
eration is deactivated, the transmitter will
return to MANUAL OFF Mode.
Program Operation will cycle fireplace
ignition ON and OFF based on time set-
tings (2 weekend periods and 2 weekday
periods) and thermostat settings. Press
the MODE/SET Button or wait for 15
seconds to advance to each subsequent
program setting.
Pilot Method (same as Thermostat
Mode): Continuous/Standing Pilot
only (Intermittent Pilot Ignition (IPI)/
Spark-to-Pilot not allowed).
• Pilot flame will remain ON when Main
Flame Cycles ON and OFF.
26
OPERATION
Continued
www.SuperiorFireplaces.US.com
To enter Program Setup, touch and hold
the TIME/PROG Zone for 5 seconds.
Program OFF LCD Displays:
• MODE Zone: OFF
• ROOM TEMP Zone: Measured tempera-
ture is displayed
• SET TEMP Zone: Blank
• TIME/PROG Zone: Current day indica-
tor, current time, and Program status
(P1- OFF or P2-OFF) is displayed
• FLAME Zone: Blank
Program ON LCD Displays:
• MODE Zone: THERMO and either ON
or OFF is displayed
• ROOM TEMP Zone: Measured tempera-
ture is displayed
• SET TEMP Zone: SET TEMP is dis-
played
• TIME/PROG Zone: Current day indica-
tor, current time, and Program status
(P1- ON or P2-ON) is displayed
• FLAME Zone:
If Thermostat is ON, A Flame Icon and
flame setting level number is displayed.
If Thermostat is OFF, display is blank.
Program Disable Feature
The Program Mode (described above)
may be disabled for applications where
a program operation is not allowed or
undesirable. When Program Mode is
Disabled:
• The user will not be able to activate
Program Mode
• The user will not be able to enter
Program Setup or edit Program Mode
settings.
• The TIME/PROG zone will continue to
display the Clock and Day of week, but
none of the icons associated with Pro-
gram Mode will be displayed.
To disable or re-enable the Program
Mode, the transmitter must be in MAN-
UAL OFF Mode, then touch and hold
the TIME/PROG Zone and the DOWN
Button simultaneously for 10-seconds.
The LCD screen will go blank except
either PROGRAM and OFF (OFF display
in MODE Zone) or PROGRAM and ON
(ON display in MODE Zone) will flash
3-times (0.5-seconds OFF, 0.5-seconds