Operation - Superior VRT4032ZEN Installation And Operation Instruction Manual

Unvented (vent-free) radiant faced fireplace system with logs and thermostat blower
Table of Contents

Advertisement

FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not fol-
low these instructions exactly,
a fire or explosion may result
causing property damage, per-
sonal injury or loss of life.
A. This appliance is equipped with an
ignition device which automatically
lights the pilot. Do not light pilot by
hand.
B. BEFORE LIGHTING smell all around
the appliance area for gas. Be sure to
smell next to the floor because some
gas is heavier than air and will settle
on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do
not use any phone in your building.
• Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.
• If you cannot reach your gas supplier,
call the fire department.
C. Do not use this appliance if any part
has been under water. Immediately call
a qualified service technician to inspect
the appliance and to replace any part of
the control system and any gas control
which has been under water.
LIGHTING
INSTRUCTIONS
WARNING: You must operate
this fireplace with the fireplace
screen in place. Make sure fire-
place screen is installed before
running fireplace.
NOTICE: During initial operation
of new fireplace, burning logs
will give off a paper-burning
smell. Open damper or window
to vent smell. This will only last
a few hours.
22

OPERATION

www.SuperiorFireplaces.US.com
1. STOP! Read the safety information in
column 1.
2. Make sure equipment shutoff valve is fully
open.
WARNING: Burners will
come on automatically within
one minute when the selector
switch is in the ON position after
the pilot is lit.
3. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the
floor. If you smell gas, STOP! Follow "B"
in the safety information, column 1. If you
don't smell gas, go to the next step.
4. Press any button on the remote to power
the remote on. Press the MODE zone or
the MODE/SET Button to start the unit.
You will hear a beep from the control
module and the pilot will start to light the
unit.
Note: You may be running this heater
for the first time after hooking up to gas
supply. If so, you may have to restart the
unit several times to allow the air to bleed
from the system.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
TO TURN OFF GAS
TO APPLIANCE
1. Once you have activated the screen
press the MODE Zone or MODE/SET
Button until you see OFF.
2. Close equipment shutoff valve (see Figure
21, page 16).
126867-01A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vrt4032zepVrt4036zenVrt4036ze

Table of Contents