Superior VRT43PFWS Installation And Operation Instructions Manual

Superior unvented (vent-free) firebox

Advertisement

Quick Links

P/N 126706-01 Rev.A 02/2014
P126706-01
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
WARNING: Carefully review the instructions supplied with the decorative type unvented room heater for
the minimum fireplace size requirement.
Do not install the appliance in this firebox, unless this firebox meets the minimum dimensions required for
the installation.
WARNING: For use only with a listed, gas-fired unvented decorative room heater not to exceed 40,000
Btu/H.
Do not build a wood fire.
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Installation and Operation Instructions
Superior
PFS
Models
®
US
Unvented (Vent-Free) Firebox
TM
VRT43PFWS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VRT43PFWS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Superior VRT43PFWS

  • Page 1 Superior Unvented (Vent-Free) Firebox P/N 126706-01 Rev.A 02/2014 Models ® VRT43PFWS P126706-01 INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. WARNING: Carefully review the instructions supplied with the decorative type unvented room heater for the minimum fireplace size requirement.
  • Page 2: Table Of Contents

    WARNING: Improper installation, adjustment, al- teration, service or maintenance can cause injury or property damage. Refer to this manual for correct in- stallation and operational procedures. For assistance or additional information consult a qualified installer, service agency or the gas supplier. TABLE OF CONTENTS Safety ..............
  • Page 3 SAFETY Continued 1. This firebox shall not be installed in a Due to high temperatures, the bedroom or bathroom. appliance should be located out 2. Never install the firebox of traffic and away from furniture • in a recreational vehicle and draperies.
  • Page 4: Local Codes

    LOCAL CODES Install and use firebox with care. Follow all State of Massachusetts: The installation local codes. In the absence of local codes, must be made by a licensed plumber or use the latest edition of The National Fuel Gas gas fitter in the Commonwealth of Mas- Code ANS Z223.1/NFPA 54*.
  • Page 5: Product Specifications

    " " 4" " PRODUCT SPECIFICATIONS 1/2" " " 24" 5/8" 4" " " " 1/2" " 4" 4" (Edge of 24" Brick Liner) 5/8" 3" TYP. " " " " 4" " 4" (Edge of 40" Brick Liner) " 3"...
  • Page 6: Air For Combustion And Ventilation

    AIR FOR COMBUSTION AND VENTILATION Unusually Tight Construction WARNING: This appliance The air that leaks around doors and windows shall not be installed in a room may provide enough fresh air for combustion and ventilation. However, in buildings of un- or space unless the required usually tight construction, you must provide volume of indoor combustion...
  • Page 7 AIR FOR COMBUSTION AND VENTILATION Continued DETERMINING FRESH-AIR FLOW 4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/ FOR FIREBOX LOCATION Hr used. Determining if You Have a Confined or _______ Btu/Hr (maximum the space can Unconfined Space support) Use this work sheet to determine if you have...
  • Page 8: Installation

    AIR FOR COMBUSTION AND VENTILATION Continued VENTILATION AIR Ventilation Air From Outdoors Provide extra fresh air by using ventilation Ventilation Air From Inside Building grills or ducts. You must provide two perma- This fresh air would come from an adjoining nent openings: one within 12"...
  • Page 9 INSTALLATION Continued C. When the firebox is installed on carpet- CAUTION: Log appliances ing or other combustible material, other installed in this firebox create than wood flooring, the firebox should be installed on a metal or wood panel extend- warm air currents. These currents ing the full width and depth of enclosure.
  • Page 10: Firebox Installation

    INSTALLATION Continued Mantel Clearances for Built-In firebox in this manner. Installation 1. Frame in rough opening. The firebox If placing custom mantel above built-in fire- framing should be constructed of 2 x 4 box, you must meet the minimum allowable lumber or heavier.
  • Page 11 INSTALLATION Continued IMPORTANT: When finishing your firebox, WARNING: Framing may be combustible materials such as wall board, placed or rest against fireplace gypsum board, sheet rock, drywall, plywood, etc. may be butted up next to the sides and spacer, however; framing must top of the firebox.
  • Page 12 INSTALLATION Continued the gas line into the rear of the firebox (see CAUTION: Do not use exces- Figure 11). sive force to remove the knock- If a sediment trap (not supplied) is not incor- porated as a part of the gas utilization equip- out.
  • Page 13 INSTALLATION Continued HARD-WIRING FIREBOX Prepare incoming black iron gas line with Teflon tape or pipe joint compound (check with This model can be hard-wired to the duplex local codes as to the use of Teflon tape). Com- outlet located inside the firebox bottom if pounds used on threaded joints of gas piping desired.
  • Page 14: Operating Guidelines And Maintenance Instructions

    INSTALLATION Continued to the receptacle must be provided for use CAUTION: Do not clean hood with the optional blower kit whether installed with abrasive cleanser. Use only during or after initial firebox installation. You may not be able to install a supply connection regular household cleaners and after the final installation is completed.
  • Page 15: Replacement Parts

    REPLACEMENT PARTS Note: Use only original replacement parts. When calling, have ready: This will protect your warranty coverage for • your name parts replaced under warranty. • your address Contact authorized dealers of this product. • model and serial numbers of your appliance If they can’t supply original replacement •...
  • Page 16: Parts

    PARTS MODEL VRT43PFWS Typ. Typ. 17** 10** 17** 17** 17** 11** 17** Typ. 17** 17** 17** 17** **These items are used on both sides of fireplace. www.SuperiorFireplaces.US.com 126706-01A...
  • Page 17 PARTS MODEL VRT43PFWS This list contains replaceable parts used in your firebox. When ordering parts, follow the instructions listed under Replacement Parts on page 15 of this manual. PART DESCRIPTION QTY. Firebox Assembly Firebox Bottom Firebox Top 23982 Top Spacer...
  • Page 18: Warranty

    THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior™ Brand gas fireplace, Stove or Insert ("Product") to be free from defects in materials and workmanship at the time of manufacture. The Product body and firebox carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against thermal breakage only.
  • Page 19 WARRANTY KEEP THIS WARRANTY Model (located on product or identification tag) _____________________________ Serial No. (located on product or identification tag) __________________________ Date Purchased __________________________ Keep receipt for warranty verification. www.SuperiorFireplaces.US.com 126706-01A...
  • Page 20 1508 Elm Hill Pike, Suite 108 Nashville, TN 37210 126706-01 1-800-655-2008 Rev. A www.IHP.US.com 02/14 P126706-01...

Table of Contents