PRODUCT IDENTIFICATION

Pebble Pan
Access Door
Figure 1 - Outdoor Linear Fireplace
CAUTION: This fireplace creates warm air cur-
rents. These currents move heat to wall surfaces next
to fireplace. Installing fireplace next to vinyl or cloth
wall coverings or operating fireplace where impurities
(such as, but not limited to, tobacco smoke, aromatic
candles, cleaning fluids, oil or kerosene lamps, etc.)
in the air exist, may discolor walls or cause odors.
Note: Standoff spacers are attached to the sides and top of your
fireplace, these spacers can be placed directly against wall or fram-
ing materials.
IMPORTANT: Make sure fireplace is level. If fireplace is not level, burner
will not work properly.
Use dimensions shown for rough openings to create the easiest
installation (see Figures 2 thru 5, page 5).
CHECK GAS TYPE
Use the correct gas type (natural or propane/LP) for your fireplace.
If your gas supply is not correct, do not install fireplace. Call dealer
where you bought fireplace for proper type gas.
WARNING: This appliance is equipped for either
natural gas or propane/LP gas but not both. Gas type
is indicated on the rating plate. Field conversion is
not permitted.
4
Top
Spacers
SuperiorFireplaces.US.com
OPERATION
This fireplace is clean burning. It requires no outside venting. There is
no heat loss out a vent or up a chimney. Heat is generated by realistic
flames. This fireplace is designed for outdoor use only. It has been
tested and approved to ANSI Z21.97 standard for outdoor decorative
gas appliance and CAN 1-2.21-M85 standard for gas-fired appliance
Nailing
for outdoor installation.
Flange

INSTALLATION

INSTALLATION CLEARANCES
WARNING: Maintain the minimum clearances. If you
can, provide greater clearances from floor, ceiling and
adjoining wall.
Carefully follow the instructions below. This will ensure safe instal-
lation.
CLEARANCES
Minimum clearances to combustibles for the fireplace are as follows:
*Back and sides
Perpendicular walls
Floor (From bottom of Fireplace)
Ceiling (From top of opening)
Top of Standoffs
* For back and sides of fireplace, do not pack with insulation or other
materials.
OUTDOOR ENCLOSURE REQUIREMENTS
Must conform to one of the following conditions:
• With walls on all sides, but with no overhead cover;
• Within a partial enclosure which includes an overhead cover and
no more than two side walls. These side walls may be parallel,
as in breezeway or at right angles to each side; or
• Within a partial enclosure which includes an overhead cover
and three sidewalls, as long as 30% or more of the horizontal
periphery of the enclosure is permanently open.

PRODUCT FEATURES

1"
8"
0"
42"
0"
127035-01C