Test Pressures Equal To or Less Than
1/2 PSIG (3.5 kPa)
1. Close equipment shutoff valve (see
Figure 21).
2. Pressurize supply piping system by either
opening propane/LP supply tank valve
for propane/LP gas or opening main gas
valve located on or near gas meter for
natural gas, or using compressed air.
3. Check all joints from gas meter to equip-
ment shutoff valve for natural gas or pro-
pane/LP supply to equipment shutoff valve
for propane/LP (see Figures 22 and 23).
Apply noncorrosive leak detection fluid to
all joints. Bubbles forming show a leak.
4. Correct all leaks at once.
Equipment
Shutoff
Valve
Figure 21 - Equipment Shutoff Valve
Gas Control Valve
Figure 22 - Checking Gas Joints for
Natural Gas
Equipment Shutoff Valve
Gas Control Valve
Figure 23 - Checking Gas Joints for
Propane/LP Gas
16
INSTALLATION
Continued
Open
Closed
Equipment
Shutoff
Valve
Gas Meter
Propane/LP
Supply Tank
www.SuperiorFireplaces.US.com
PRESSURE TESTING FIREPLACE GAS
CONNECTIONS
1. Open equipment shutoff valve (see Fig-
ure 21).
2. Open main gas valve located on or near
gas meter for natural gas or open pro-
pane/LP supply tank valve.
3. Make sure control knob of fireplace is in
the OFF position.
4. Check all joints from equipment shutoff
valve to gas control valve (see Figures 22
or 23). Apply noncorrosive leak detection
fluid to all joints. Bubbles forming show a
leak.
5. Correct all leaks at once.
6. Light fireplace (see Operation, page 22).
Check all other internal joints for leaks.
7. Turn off fireplace (see To Turn Off Gas to
Appliance, page 22).
POWER SUPPLY AND BATTERY
INSTALLATION
It is helpful to have a flashlight so you can
see the connections as described below. Lo-
cate the battery power supply. It is the black
box with the red and black wires. Locate the
control module (see Figure 24). Connect the
battery power supply to the control module
by plugging the battery power supply to the
mating receptacle on the control module. The
receptacle is located on the side of the black
control module next to the word "SUPPLY"
which is molded in the control module's black
housing (see Figure 24). Be certain to push
the plug fully into the receptacle. Install bat-
teries in the battery power supply and hand
held remote control.