4. SYSTEM MENU
4.9

How to Adjust (Calibrate) Incoming Data

Use the [Data Calibration] menu to adjust offsets for data input to the FI-70.
1. Access the [System] menu using the procedure outlined on page 4-1.
2. Press the software keys to select [Data Calibration], then press the function key.
Adjust(STW):
Wind Damping:
Adjust(W Speed):
W Angle Response:
3. Press the software keys to select the appropriate data to offset, then press the
function key.
The data which can be offset is shown in table below.
Adjust (STW)
Wind Damping
Adjust (W Speed)
W Angle Response
Offset (W Angle)
Offset (HDG)
Offset (Depth)
Offset (W Temp.
4. Press the software keys to select the required offset, then press the function
key.
5. Press the Menu/Back key twice to close the menu.
4-12
Data Calibration
1.00(18.0kn)
----------------
0s(20.0kn)
1.00(5.0kn)
0s
Ent
Offset the speed displayed.
Offset the delay between wind sensor and FI-70.
Offset the wind speed displayed.
Sets the needle response speed. Lower settings give a
faster response (needle movement).
Offset the wind angle.
Offset the heading.
Offset the depth.
Offset the water temperature.
The value after
calibration is shown
in parentheses.