Raid 1+0 Configurations; Integrated Ata Raid Configuration Utility - HP ProLiant ML310 Maintenance And Service Manual

Hide thumbs Also See for ProLiant ML310:
Table of Contents

Advertisement

If there is not an online spare configured:
1. Power down the server, and then replace the failed drive.
2. Reboot the server.
3. Rebuild the array, choosing one of the following options:
a. Run the Integrated ATA RAID Configuration Utility by pressing the F8 key, and
b. Let the auto-rebuild take place when the operating system is up and running.
Refer to "Integrated ATA RAID Configuration Utility" in this chapter for information on the
utility menu options.

RAID 1+0 Configurations

NOTE: RAID 1+0, RAID 0+1, and RAID 10 are used synonymously.
Four ATA hard drives are required to support a RAID 1+0 configuration.
In a RAID 1+0 situation, multiple drive failures can be handled as long as both elements of a
mirror have not failed.
To rebuild the array:
1. Power down the server, and then replace the failed drive.
2. Reboot the server.
3. Rebuild the array, choosing one of the following options:
a. Run the Integrated ATA RAID Configuration Utility by pressing the F8 key, and
b. Let the auto-rebuild take place when the operating system is up and running.
Refer to "Integrated ATA RAID Configuration Utility" in this chapter for information on the
utility menu options.

Integrated ATA RAID Configuration Utility

The setup screen of the Integrated ATA RAID Configuration Utility has three menu
windows:
Array Information
Physical Drive Information
Help Information
HP ProLiant ML310 Server Maintenance and Service Guide
then run Rebuild.
or
then run Rebuild.
or
Removal and Replacement Procedures
2-21

Advertisement

Table of Contents
loading

Table of Contents