RECONNECT PROCEDURE

Multiple voltage machines are shipped connected
to the highest input voltage listed on the
machine's rating plate.
machine, check that the Reconnect Panel in the
Input Box Assembly is connected for the proper
voltage.
CAUTION
Failure to follow these instructions can cause
immediate failure of components within the
machine.
__________________
To reconnect the machine to a different voltage,
change the position of the power straps (links) on
the reconnect panel assembly. Follow The Input
Supply Connection Diagram located on the inside
of the access door.
1. For 208/230/460 VAC machines, see
Figure A.3a.
2. For 460/575 VAC machines, see Figure
A.3b.
INSTALLATION
Before installing the
460V
460 V., 60HZ.
GND.
L1
L2
USE FERRULE
#10 AWG ONLY
230V
230 V., 60HZ.
GND.
L1
L2
208V
208 V., 60HZ.
GND.
L1
L2
FIGURE A.3a-Voltage Link Positions for
208/230/460 VAC machines.
575V
575 V., 60HZ.
GND.
L1
L2
USE FERRULE
#10 AWG ONLY
460V
460 V., 60HZ.
GND.
L1
L2
FIGURE A.3b - Voltage Link Positions for
460/575 VAC machines.
A-6
LINK POSITIONS
LINK
LINK POSITIONS
LINK
LINK POSITIONS
LINK
LINK POSITIONS
LINK
LINK POSITIONS
LINK