F-19
TORCH, TORCH CABLE ASSEMBLY, INTERNAL TRIGGER,
8. Disconnect Plug J5 from its
header on the Control Board.
9. Test for zero ohms (continuity)
from the following test points on
Plug J5 header to the 4-pin
leads on the bulkhead of the
machine (See Figure F.7):
- Pin 4J5 (lead #4) to 4-pin pin
#4
- Pin 3J5 (lead #2) to 4-pin pin
#2
- Pin 6J5 (lead #336) to 4-pin
pin #1
- Pin 8J5 (lead #337) to 4-pin
pin #3
a. If any of the above tests do
not agree with the expected nor
mal resistance specifications,
then Plug J5 on the Control
Board,
receptacle, or the a s s o c i a t e d
wiring must be repaired.
b. If all of the above tests are
within the normal resistance
specifications, continue with test
procedure.
10. Re-connect Plug J5 back into its
header.
11. Test for 24 VAC between Pin 5J5
(lead
(lead # 335) on Plug J5.
a. Carefully insert the volt/ohm
PRO-CUT 60
TROUBLESHOOTING & REPAIR
AND SAFETY CIRCUIT TEST
the
torch
C1)
and
Pin
(Multimeter) probes into the
back of the J5 plug into pin
cavity 5J5 (lead C1) and pin
cavity
7J5
(lead
#335).
See Figure F.1.
b. Connect
PRO-CUT 60.
c. Turn ON/OFF Power Switch
to ON.
d. Read meter.
- If 24 VAC is NOT present,
continue with test procedure.
12. Turn ON/OFF Power Switch to
OFF.
13. Disconnect main input power to
machine.
14. Perform
DISCHARGE PROCEDURE.
15. Check Plug J10 and Plug J5 and
associated wiring for loose or
4-pin
faulty connections.
16. Disconnect
Header J10.
17. Test for continuity (zero ohms)
between 3J10 and 6J10 on
Control Board Header J10.
a. If continuity is not indicated,
the Control Board could be
faulty.
7J5
18. Perform MAIN TRANSFORMER
TEST.
19. Replace the Control Board if all
of the above tests are within
normal specifications.