F-45
b. Rinse the heat sink surface
c. Apply a .002" to .005" coat of
d. Press the SCR Module onto
PRO-CUT 60
TROUBLESHOOTING & REPAIR
SCR MODULE REMOVAL
with alcohol or acetone.
joint compound evenly to the
heat sink mounting surface
and
the
SCR
Module
mounting
surface.
Lincoln
Joint
Compound
T12837, or equivalent, such
as Dow Corning #340.
the
heat
sink
surface.
Remove the module to make
sure enough joint compound
has been applied.
When
removed,
both
surfaces
should have an even texture
with no bare spots.
If this
even-textured look does not
appear, re-apply the joint
compound.
e. Mount the SCR Module on
the heat sink with the 4mm
socket head cap screws to
35 in/lbs (3.9 N.M.). Partially
tighten each cap screw one
at a time to avoid uneven
torque on the base plate.
Use
8. Install
Power
POWER BOARD REMOVAL/
REPLACEMENT PROCEDURE.
Board.
See