Observe Safety Guidelines
detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
No
LEDs
light
when
ON/OFF Power Switch is turned
"ON". Machine is dead. Fan
runs normally.
The "MACHINE ON" LED is lit
and the "SAFETY" LED is lit.
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln
Electric Service Department for technical troubleshooting assistance before you proceed call 216-383-2531 or 1-800-833-9353.
TROUBLESHOOTING & REPAIR
POSSIBLE AREAS OF
MISADJUSTMENT(S)
OUTPUT PROBLEMS
the
1. Make sure input voltage
corresponds
nameplate voltage.
2. Make certain the reconnect
panel is configured properly
for
input
voltage
applied to PRO-CUT 60
1. Push the "SAFETY RESET"
button, the LED should go
out. This circuit sometimes
trips on power up or because
of "noise". If the circuit can
be reset, it is OK to continue.
2. Maintain proper stand-off
while cutting (.10" to .15").
Too long a stand-off may
cause nuisance safety trips.
3. Check torch consumables.
Replace if needed.
4. Replace the torch and cable
assembly.
CAUTION
TROUBLESHOOTING GUIDE
RECOMMENDED
COURSE OF ACTION
1. Check plug J7 (located on
to
machine
the Control Board) and
associated wires for loose
or faulty connections.
2. Check Plug J9 on Status
Board and J8 on Control
being
Board for loose or faulty
connections
3. Test for 24 VAC between
leads C2 and H6 (plug J7)
on Control Board. Refer to
wiring diagram.
a. If the 24 VAC IS NOT
present or voltage is very
low, the main transformer
could be faulty.
Main Transformer Test.
b.
present at leads C2 to H6,
the Control Board could be
faulty. Replace.
1. The
assembly may be faulty.
Perform Torch, Torch Cable
Assembly,
Trigger and Safety Circuit
Tests.
2. Check for continuity (zero
ohms) between leads #336
and #337 from the torch
4-pin connector on the
machine to plug J5 on the
Control Board.
wiring diagram.
3. Check Pilot bleed resistor
R3. Normal is 40 ohms.
See wiring diagram.
4. The control board could be
faulty. Replace.
5. Perform Main Transformer
Test.
F-4
Perform
If the 24 VAC is
torch
and
cable
and
Internal
Refer to
PRO-CUT 60