* Installation of the Receiver must be completed before installing non-combustible facing.
All three pieces (top, 2 sides) are now supplied to meet the non combustible requirements. Previously only the top was supplied.
Calcium silicate board is a high - grade material
with cement, quartz, natural and selected
minerals as the main raw materials. It is widely
used for partitions and ceilings in buildings.
It is fi re proof and earthquake proof.
If fi nishing the wall above the unit with materials
such as tile, brick, marble, etc. non-combustible
board available from the building supply store
can be used.
Note: Calcium Silicate is 1/2' thick
Caution:
The non-combustible board supplied with this unit can
be damaged if dropped or struck. Handle with care.
1) Using drywall screws - secure non combustible material
around unit, framing and top nailing strip every 6 inches.
Important Note: To avoid cracking the board - pre-drill holes prior to
securing to unit/ framing.
2) Wipe any debris/dust from the non combustible
material and drywall.
3) Prior to securing it is mandatory to prime the facing and edges
using a quality primer. This will ensure proper adhesion of both the
tape and mud. The supplied board is very porous.
Failure to follow this procedure will result in cracked seams.
4) Tape the seams using a mesh type tape.
5) Mud seams as normal. We recommend using a
product called Durabond high strength compound - for the fi rst coat.
This product can be found at any hardware store.
Mud must be cured as per manufacturer's recommendations.
6) Prime wall for a second time for proper adhesion of paint
7) Paint walls using a high quality paint which will withstand
the high temperatures being emitted from this appliance.
Regency Horizon™ HZ40E-2 Gas Fireplace

NON-COMBUSTIBLE REQUIREMENTS

Metal Stud

NON-COMBUSTIBLE FACING INSTALLATION

51-5/16" (1303mm)
Non-combustible
Non-combustible
10"
(252mm)
May be combustible (ie. 1/2" drywall)
5-11/16"
(144mm)
Non-combustible board
shipped with unit.
INSTALLATION
Metal Stud (header)
on edge
Material
Non-combustible board
shipped with unit.
Non-combustible board-faces and edges
MUST BE PRIMED.
Metal Stud
15