120 Volt AC power is needed for the fan. The fan can be hard wired if desired.
The receptacle box should be installed on the right hand side of the unit
by a qualifi ed electrician. The neutral (wider) slot of the polarized receptacle
should be at the top.
Unit must be grounded at all times. Do not cut the ground terminal off
under any circumstances.
Note: Follow instructions below - if unit has not yet been installed - otherwise
skip to existing installtions section.
1) Remove 8 screws to remove front access panel.
2) Remove 2 top screws and loosen 2 bottom screws to remove side access
panel.
3) Install fan control module (FCM) into bracket on the inside of the panel,
plug the (FCM) into the outlet in the unit - reinstall the panel with 4 screws
from step 2.
4) Proceed to Step 11.
Regency Horizon™ HZ40E-2 Gas Fireplace

GTMF REMOTE INSTALLATION

INTO EXISTING INSTALLATIONS
1) Shut off the gas and power supply to the unit.
2) Remove the faceplate or door frame - see instruction in manual.
3) Remove the glass door.
a) Remove the 3 screws shown below at the bottom of the glass
.
door
b) Swing the door out 45
o
from the bottom and lift up and out.
4) Remove the inner panels - reverse of "Inner panel Installation" in the
installation manual.
5) Remove the burner tray cover by lifting up and out as shown below.
* Prior to removing burner - remove crystals, pebbles, spa stones and inner
panels - if installed.
INSTALLATION