Optional Fan Wiring Diagram; Without Proflame Gtmf System - Regency Fireplace Products Regency Horizon HZ40E-NG2 Owners & Installation Manual

Gas fireplace
Table of Contents

Advertisement

Lockwasher
Star washer
(for mobile home)
Nut
Fan
ground wire
Electrical Connection Alternative Scheme "A",
Power at Stove
Wall Junction Box
~
Wire Nuts
14 AWG wire
*Wire Clamp
*Receptacle Box
inside stove
*Receptacle
(dedicated use
by stove fan only)
Copper Ground
120 Volts
White (Neutral)
60 Hz
Black (Hot)
14 AWG wire
Regency Horizon™ HZ40E-2 Gas Fireplace

OPTIONAL FAN WIRING DIAGRAM

WITHOUT PROFLAME GTMF SYSTEM

#8 Ground Lug
120V AC
60 Hz
*Speed Control
Switch with
lead wires
(Regency)
120 Volts
60 Hz Copper Ground
Wire Nuts
* = supplied with fan kit
Other parts are to be supplied
by electrician or installer
Black
White
Neutral
Green
Live
Ground
Black
Electrical Connection Alternative Scheme "B",
Power at Switch
Wall Junction Box
~
Black (Hot)
White (Neutral)
Wire
Caution: Ensure that the wires do not touch any
hot surfaces and are away from sharp edges.
CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can cause
improper and dangerous operation.
INSTALLATION
Fan
Fan
Black
Black
Red
Fan Thermodisc
(normally open)
*Speed Control
Switch with lead wires
Wire Nuts
Black
White
14 AWG wire
Ground
*Wire Clamp
*Receptacle Box
inside stove
*Receptacle
(dedicated use
by unit fan only)
Ground
41

Advertisement

Table of Contents
loading

This manual is also suitable for:

Regency horizon hz40e-lp2

Table of Contents