DIAGNOSTIC: Automatic
Performs a five-minute automatic test with wa-
ter functions to check major washer functions
(door can be open). Press the same button
used in step 2 to advance through automatic
test steps.
NOTE: Basket must be floating in order to
agitate. Step C1 must be allowed to complete
before advancing to step C5.
Two-Digit
Machine Function
Indicator
C0
Slow spin to 23 rpm.
Warm water fills through
Fresh and Detergent
valves, then Fresh valve
until basket floats
C1
(disengages); then
washer continues filling
through Fresh and
Detergent valves to
minimum water level.
Cold water fills through
Bleach valve for
C2
10 seconds.
Hot water fills through
Fabric Softener valve
C3
for 10 seconds.
NOTE: Step will occur
but no water can be
dispensed with models
that do not have a
fabric softener valve.
Warm water fills through
Detergent valve for
C4
10 seconds.
C5
Agitate for 15 seconds.
Recirculate for
C6
10 seconds.
Drain to basket engaged
C7
plus timed drain for
10 seconds.
Drain & slow spin
C8
23 rpm.
C9
Coast to 0 rpm.
(none)
(Test
End of cycle beep.
ends)
DIAGNOSTIC: Unsuccessful Entry
If entry into diagnostic mode is unsuccessful
(see steps 1 and 2 of Activation of Automatic
Diagnostic Test Mode), refer to the following
indications and actions:
Recommended Procedure
If no spin go to Manual: Motor,
Spin.
If no water or fill temperature is
wrong, go to Manual: Water
Valves.
If basket does not float or
disengage, determine cause of
friction.
If no water in bleach cup go to
Manual: Water Valves.
If no water in fabric softener cup
go to Manual: Water Valves.
If no water in detergent cup
go to Manual: Water Valves.
If no wash action go to
Manual: Motor, Agitate.
If water is not being recirculated
go to Manual: Pumps.
If water is not draining go to
Manual: Pumps.
If basket does not engage
determine cause of friction.
If drain pump is not on go to
Manual: Pumps.
If basket is not turning go to
Manual: Motor.
If basket does not stop spinning
within 5 seconds, press PAUSE/
CANCEL and restart test.
If no end of cycle beep, make sure
cycle signal is on. From Setting
Mode, pressing buttons should
sound valid key press beep.
Indication 1: None of the indicators or dis-
play turns on.
Action: Press POWER button to enter setting
mode.
If indicators come on, try to change the
function for the button used to activate
the diagnostic test mode. If that button
fails to change the function, something
is faulty with the button, and it is not
possible to enter the diagnostic mode.
If no indicators come on after pressing
POWER button, go to TEST #1.
Indication 2: Fault code flashes from the
display.
Action: Review the Display Fault/Error Codes
table for the recommended procedure.
DIAGNOSTIC: Saved Fault Codes
If there are saved fault codes (as indicated in
step 3 of Activation of Automatic Diagnostic
Test Mode), the most recent fault code will be
displayed and alternately show "F" and "XX"
where XX is the fault code, and all the cycle
selector indicators flash.
Press and release the
same button used to
activate Diagnostics
Repeat
Repeat
Repeat
ACTIVATION OF MANUAL
DIAGNOSTIC TEST MODE
1.
Carefully read and perform steps 1 and 2
under Activation of Automatic Diagnostic
Test Mode, and press the same button
once during the 5 second display time of
the 88.
NOTE: If the button is not pressed within
5 seconds, the Automatic test will start
(after saved fault codes).
6-5
Second most recent fault code is
displayed.
Third most recent fault code is displayed.
Fourth most recent fault code is displayed.
All indicators momentarily turn off, then
stay on. After 5 seconds, Automatic test
cycle begins.
NOTE: Fault codes are retained.