Maytag MTW6300TQ Bravos Service Manual page 70

Automatic washer
Table of Contents

Advertisement

2.
If done successfully, a single beep oc-
curs and the two-digit display shows the
control ID# for 3 seconds, then displays
00 and the Add A Garment indicator LED
flashes. See Diagnostic: Manual.
DIAGNOSTIC: Manual
Assumes Manual Diagnostic mode has been
entered, two-digit display shows 00, and ADD
A GARMENT indicator LED is flashing.
NOTE: If there is no activity (button press,
cycle select) within 5 minutes, the control au-
tomatically exits Diagnostic mode and enters
standby mode.
Manual: Water Valves
To check FRESH valve select or press the
following:
WHITES • START (turns on Fresh valve,
cycle indicator flashes) • WASH/RINSE
TEMP (enables fill of Hot, Warm, Cool
or Cold or no water according to WASH/
RINSE TEMP selection and indicator) •
START (turns off Fresh valve, cycle indi-
cator is steady on).
To check DETERGENT valve select or press
the following:
SUPER WASH • START (turns on De-
tergent valve, cycle indicator flashes) •
WASH/RINSE TEMP (enables fill of Hot,
Warm, Cool or Cold or no water accord-
ing to WASH/RINSE TEMP selection and
indicator) • START (turns off Detergent
valve, cycle indicator is steady on).
To check FABRIC SOFTENER valve select
or press the following:
NORMAL • START (turns on Fabric
Softener valve, cycle indicator flashes) •
WASH/RINSE TEMP (enables fill of Hot,
Warm, Cool or Cold or no water accord-
ing to WASH/RINSE TEMP selection and
indicator) • START (turns off Fabric Soft-
ener valve, cycle indicator is steady on).
To check BLEACH valve select or press the
following:
WRINKLE CONTROL • START (turns on
Bleach valve with cold water, cycle indi-
cator flashes) • START (turns off Bleach
valve, cycle indicator is steady on).
NOTE: Washer can only fill cold through
Bleach valve.
If any valve fails to turn on go to TEST #2.
Manual: Pumps
Select CLEAN WASHER or SPIN ONLY.
Press and release:
START
Repeat
Repeat
Repeat
If pumps fail to turn on go to TEST #7.
6-6
Turns on recirculation pump, cycle
indicator is steady on.
Turns off recirculation pump, indicator
is steady on.
Turns on drain pump, indicator flashes.
Turns off drain pump, indicator is
steady on.

Advertisement

Table of Contents
loading

Table of Contents