NFP Storage Manager 1.1 User's Manual

UPS Management

NASolution Network Filer Plus currently supports only APC Smart
Series UPS, both via serial connection or SNMP.
Control UPS by serial port
Connect NP1040 NAS server's power cords to UPS, and the APC
RS-232 cable (part number 940-0024C or 940-0020B) to COM1 port
of NP1040 NAS server. In NFP Storage Manager, go to ToolkitàUPS
Management, and select Control UPS by serial port, then select the
time for Probing interval and Delayed before shutdown. The system
will use the time interval set for Probing interval to check the status of
the UPS. If an AC power failure or a low battery warning occurs, the
system will wait for the time entered under Delayed before shutdown
before shutting down, unless the problem is remedied during that
time.
Control UPS by SNMP
Connect NP1040 NAS server's power cords to the UPS and the UPS
88
Chapter 4. Using NFP Storage Manager 1.1