Fan Installation - Kingsman Zero Clearance Installation Instructions Manual

Direct vent gas fireplace
Table of Contents

Advertisement

Fan installation Instructions for ZDV6000/3320/3318/3318MQ
with or without CVCK (Clean View Circulating Kit).
Note: Install Fan Kit Before Installing optional CVCK (Clean
View Circulating Kit).
If CVCK has been installed into framing additional access is
provided by removing screws from bottom panel of CVCK. See
Installing Clean View Kit (CVCK).
1.
Slide fan housing into unit and place over 2 Fan Retainer Tabs. Tabs
are pre punched and bent up (*Note: on 6000/3320 units, these
Tabs are located on the right side of the unit). Rubber grommets
at the base of the fan should fit snugly over the tabs.
2.
For Fan Disc Installation these units have been installed with a sliding
track system. Install the Thermodisc provided with the Fan Kit. Place
Thermodisc into sliding assembly (Fig.1), and attach 2 leads exiting
right side of the fan housing into thermodisc. Now slide disc assembly
into thermodisc track (Fig.2). Place swivel handle of disc assembly
on track to lock into position. To service disc simply pull swivel handle
slide towards you while rotating handle to access disc.
Caution: Label all wires prior to disconnection when
servicing controls. Wiring errors can cause improper and
dangerous operation.
Verify proper operation after servicing.
Parts List:
1ea. Fan comes with 4ft cord. Two 14" leads (female ends)
1ea. Variable speed control (wall mount type)
1ea. Thermodisc
1 Thermodisc mount assembly
CAUTION: DO NOT ATTACH 120V FAN ASSEMBLY TO MILLIVOLT GAS VALVE SYSTEM
Fan Kit Installation
3.
4.
5.
Note: To service fan with CVCK Kit installed see Removing
Burner System in manual. If CVCK is finished with a MQSW
Wall Surround the MQSW may be removed by removing the
4 attachment screws and removing the MQSW
allowing access into the bottom of the fireplace to service
blower.
Electrical Services
All optional Fan Kits are equipped with a 120V, 60Hz, .4amp blower.
Note: All electric connections are to be made in accordance with
CSA Standard C22.1 – Canadian Electrical Code part I or with the
National Electrical Code, ANSI/NFPA 70 (latest edition) and /or in
accordance with local codes.
Warning: Electrical Grounding Instructions. This
appliance is equipped with a three-pronged (grounding)
plug for your protection against shock hazard and
should be plugged directly into a properly grounded
three-prong receptacle. Do not cut or remove the
grounding prong from this plug.
18
Wire Junction Box and wall mounted variable speed control to
120v. Install a duplex outlet to junction box and plug fan into
outlet.
Turn the wall switch on (clockwise). Turn fireplace on. Once the
sensor in the unit reaches operating temperature (approximately
10 to 15 minutes) the fan will turn on. The fan can be switched
off if desired by turning the wall switch fully counter clockwise.
To set the minimum fan speed, remove the variable switch from
the wall mount. Turn the variable speed wall controller to its
minimum setting (fully counterclockwise). Use the set screw on
the side of the variable speed controller to increase or decrease
the minimum fan speed (lowering the minimum fan speed will
decrease sound level created by fan).
Reinstall switch into wall mount and cover with face plate.

Advertisement

Table of Contents
loading

Table of Contents