WIRING

120 VAC POWER CONNECTION

Connect the black, white
and ground wire from the
upper junction box to the
120 Vac power supply.
Green Ground
White Neutral
Black 120 Vac
120 Vac Power Wire
1/2 HP and Dual Motor
1 HP

HEATER POWER CONNECTION

Connect the black, white and ground wire from the heater to the
120 Vac power supply as shown. When the heater switch is left in
the "ON" position, the heater will turn on and off automatically
when needed.
Green Wires Ground
White Wires Neutral
Black Wires 120 Vac
Power supply in waterproof conduit.
16 Gauge
14 Gauge
up to 150 FT
250 FT
up to 75 FT
125 FT
Switch should left in the "ON" position.
CSW Power Wires
On-Off switch for operator
12 Gauge
10 Gauge
400 FT
200 FT
To reduce the risk of SERIOUS INJURY:
DO NOT touch the heater when switch is on, heater may be
hot.
18
Use a 20 amp dedicated circuit for each
operator.
Input power 120 Vac, 60 Hz.
Earth Ground Rod Highly Recommended!
See previous page.
8 Gauge
650 FT
1000 FT
325 FT
500 FT
Power Supply
4 Gauge
2200 FT
1100 FT