WIRING DIAGRAMS
WIRING TABLE CSW200UL8™ AND CSW200ULDM8™
J #
J Pin #
J1
1
2
3
4
5
6
7
8
9
10
J2
10 Pins
J3
1
2
3
4
5
6
7
8
9
10
J5
1
2
3
4
5-7
J6
1
2
3
4
J7
1
2
3
J8
1-2
3-4
5-6
J9
16 Pins
J10
1
2
3
J11
10 Pins
J12
10 Pins
J13
10 Pins
J1
1
2
3
J2
1
2
3
4
Strike Open Push Button (10)
5
6
7
J3
1-2
Center External Loop Detector
3-4
Safety External Loop Detector
5-6
OmniControl™ Board
Signal Type
Safety Loop
Input Power Neutral
Center Loop
Input Power 120 Vac
Strike Open
Exit Loop
Radio Receiver –
Radio Receiver
Fire Dept Key Switch
Radio Receiver +
OmniControl™ Option Board
Limit Switch Red N.O.
Motor White
Normally Closed (No Wire)
Motor Black
Limit Switch Brown Com
Motor Green
Purple Com
Blue N.O.
Limit Switch Yellow Com
Limit Switch Orange N.O.
Reset Switch Red
Reset Switch Black
UL Alarm Red
UL Alarm Black
Photoelectric Sensor
Photoelectric Sensor
Relay Adapter Red
Relay Adapter White
Relay Adapter Black
Plug-In Exit Loop Wire
Plug-In Safety Loop Wire
Plug-In Center Loop Wire
1 HP Board
G M/S Link
B M/S Link
A M/S Link
Center Loop Detector
Safety Loop Detector
Exit Loop Detector
OmniControl™ Surge Suppressor
G M/S Link (G)
B M/S Link (B)
A M/S Link (A)
Fire Dept. Key Switch (7)
Fire Dept. Key Switch (8)
Strike Open Push Button (9)
Radio Receiver – (11)
Radio Receiver (12)
Radio Receiver + (13)
Exit External Loop Detector
Direction
Level (+/- 10%)
In
5 or 0 Vdc
In
0V
In
5 or 0 Vdc
In
120 Vac
In
5 or 0 Vdc
In
5 or 0 Vdc
In
0V
In
0V
In
Dry
Out
24 Vdc
Out
24 Vdc
Out
0 Vdc
Out
0V
In
5 or 0 Vdc
Out
120 Vac
In
0V
Out
120 Vac
In
0V
In
5 or 0 Vdc
In
0V
In
5 or 0 Vdc
In
In
Dry
In
In
Dry
In
Out
24 Vdc
Out
0 Vdc
In
5 or 0 Vdc
In
0V
In
5 or 0 Vdc
In
0 Vdc
In
0 Vdc
In
2 to 10 Vdc
In
2 to 10 Vdc
In
2 to 10 Vdc
In/Out
0 Vdc
In/Out
5 or 0 Vdc
In/Out
5 or 0 Vdc
In
5 or 0 Vdc
In
5 or 0 Vdc
In
5 or 0 Vdc
In/Out
0V
In/Out
5 or 0 Vdc
In/Out
5 or 0 Vdc
In
Dry
In
Dry
In
5 or 0 Vdc
In
0V
In
0V
In
5 or 0 Vdc
Out
24 Vdc
In
2 to 10 Vdc
In
2 to 10 Vdc
In
2 to 10 Vdc
37
Input Connection
External Loop Detector Wires, 120 Vac
Power, Radio Receiver, Strike Open, Key
Switch Harness
OmniControl™ Board Input
Motor(s), Limit Switches,
Maglock/Solenoid Harness
Reset Switch Input
UL Alarm and Photoelectric Sensors
Relay Adapter Module Input
Plug-In Loop Detector Wires
Not Used
Primary/Secondary Link
Plug-In Loop Detector Inputs
Primary/Secondary Link Input
Radio Receiver, Strike Open Push Button,
Fire Dept Key Switch Inputs
External Loop Detector Center, Safety, Exit
Wires Input
NOTE: See diagram on previous page.

Hide quick links:

Advertisement

Table of Contents
loading