Linking Primary/Secondary Operators - Chamberlain CSW200UL8 Owner's Manual

Elite series vehicular swing gate operator
Hide thumbs Also See for CSW200UL8:
Table of Contents

Advertisement

WIRING

LINKING PRIMARY/SECONDARY OPERATORS

Use a 20 amp dedicated power circuit for each operator.
Run low voltage 16-18 gauge wire in UL approved conduit to link operators together.
Primary Board
Surge
Suppressor
Primary/
Secondary
Connection
Shield Wire
Partial Primary/Individual Control
In order for the following operation to occur, follow the instructions.
EXAMPLE: There is a double gate, the entry gate is to be opened with a remote control and the exit gate with a free exit loop. Only one
safety loop system is to open both gates, and a fire department switch should open both gates at the same time.
1. Connect the radio receiver to entry gate only.
2. Connect the exit loop to exit gate only.
3. Connect the safety loop to both entry and exit gates (observe polarity of voltage).
4. Connect the fire department switch to both entry and exit gates (observe polarity of both operators).
Never run high voltage and low voltage wires in same conduit.
Primary/Secondary control boards are interchangeable.
Connect Primary M/S Link G to Second M/S Link G.
Connect Primary M/S Link B to Second M/S Link B.
Connect Primary M/S Link A to Second M/S Link A.
Use shielded
twisted wires for
M/S link.
Shield wire MUST
be grounded to
primary operator
Only.
NOTE: To adjust
timers, see page 30.
19
Secondary Board
NOTE: Disconnect the second
radio receiver when using a
primary/secondary setup.