Connection Of Extensions; Maximum Cabling Distances Of The Extension Wiring (Twisted Cable) - Panasonic KX-TDA600 Installation Manual

Panasonic hybrid ip-pbx installation manual
Hide thumbs Also See for KX-TDA600:
Table of Contents

Advertisement

2.9.1 Maximum Cabling Distances of the Extension Wiring (Twisted Cable)

2.9 Connection of Extensions

2.9.1 Maximum Cabling Distances of the Extension Wiring
(Twisted Cable)
Notice
If the cabling distance exceeds the maximum cabling distance above, satisfactory performance of each
terminal cannot be guaranteed.
The connected terminals will operate over the maximum cabling distance under optimum conditions.
However, the maximum cabling distance of SLTs connected to ports No. 9–24 of the ECSLC24 card
may be shorter than that of SLTs connected to the ESLC16 card.
DHLC8 Card
EMSLC16, ESLC16,
ECSLC24, CSLC16,
SLC8 Cards
192
Installation Manual
Cable
ø 0.4 mm:
ø 0.5 mm:
ø 0.6 mm:
CAT 5:
Cable
ø 0.4 mm:
ø 0.5 mm:
ø 0.6 mm:
CAT 5:
Cable
ø 0.4 mm:
ø 0.5 mm:
ø 0.6 mm:
CAT 5:
Cable
ø 0.4 mm:
ø 0.5 mm:
ø 0.6 mm:
CAT 5:
PT-interface
CS
DPT
(Basic/
High-density)
ü
Maximum Distance
222 m
347 m
500 m
347 m
Maximum Distance
500 m
720 m
830 m
720 m
Maximum Distance
140 m
229 m
360 m
229 m
Maximum Distance
698 m
1128 m
1798 m
1128 m
APT
ü
ü
PT-interface CS
(Basic/High-density)
KX-T7600 Series DPT
Other PT (DPT/APT)
and DSS Console
SLT
DSS
SLT
Console
ü
ü
ü

Advertisement