Connection Of Extensions; Maximum Cabling Distances Of The Extension Wiring (Twisted Cable) - Panasonic KX-TDE110 Installation Manual

Pure ip- pbx
Table of Contents

Advertisement

3.8

Connection of Extensions

3.8.1
Maximum Cabling Distances of the Extension Wiring
(Twisted Cable)
* The maximum cabling distance from the PBX is the same even when the KX-T7600 series DPT is the
master DPT on the Digital XDP connection.
Notice
The maximum cabling distance may vary depending on the conditions.
PT-interface CS
DHLC8 Card
MSLC16, SLC16,
SLC8 Cards
DLC16, DLC8 Cards
"
" indicates that the extension card supports the terminal.
Cable
Maximum Distance
26 AWG:
222 m (728 ft)
24 AWG:
347 m (1138 ft)
22 AWG:
500 m (1640 ft)
CAT 5:
347 m (1138 ft)
Cable
Maximum Distance
26 AWG:
500 m (1640 ft)
24 AWG:
720 m (2362 ft)
22 AWG:
830 m (2723 ft)
CAT 5:
720 m (2362 ft)
Cable
Maximum Distance
26 AWG:
140 m (459 ft)
24 AWG:
229 m (751 ft)
22 AWG:
360 m (1181 ft)
CAT 5:
229 m (751 ft)
Cable
Maximum Distance
26 AWG:
698 m (2289 ft)
24 AWG:
1128 m (3700 ft)
22 AWG:
1798 m (5897 ft)
CAT 5:
1128 m (3700 ft)
DPT
3.8 Connection of Extensions
PT-interface CS
KX-T7600 Series DPT*
Other PT (DPT/APT)
and DSS Console
APT
DSS Console
SLT
SLT
Installation Manual