Operation - Panasonic KX-TDA600 Installation Manual

Panasonic hybrid ip-pbx installation manual
Hide thumbs Also See for KX-TDA600:
Table of Contents

Advertisement

4.1.3 Operation

4.1.3 Operation
PROBLEM
When using the
speakerphone on an
APT, nothing is audible.
When using the
speakerphone/monitor
mode with a DPT,
nothing is audible.
The PT does not ring.
During a power failure,
extensions connected
to ports 1 to 4 of
EMSLC16/ESLC16/
ECSLC24/CSLC16 and
ports 1 to 2 of DHLC8/
SLC8 cards do not
operate.
Originating an outside
call, call transfer, or
conference cannot be
performed.
The LED of the CS does
not change to Green
ON.
320
Installation Manual
PROBABLE CAUSE
The HANDSET/
HEADSET selector is
set to the "HEADSET"
position.
The "HEADSET" mode
is selected by Personal
Programming,
"Handset/Headset
Selection".
The ringer volume is off.
A DPT or APT is
connected to the
extension port.
The dialling mode (tone
or pulse) is incorrect.
The corresponding
flexible button does not
exist on the PT.
CS is not connected
properly.
CS is not set for normal
operation.
The status of the port
that the CS is
connected to is Out of
Service.
<KX-TDA0158 only>
The Local Processor
(LPR) software of the
corresponding DHLC/
DLC card is not version
5.000 or later.
SOLUTION
When the headset is not used, set the
HANDSET/HEADSET selector to the
"HANDSET" position.
When the headset is not used, select the
"HANDSET" mode by Personal
Programming.
Turn on the ringer volume.
Disconnect the DPT or APT and connect
an SLT.
Set the Tone/Pulse switch to the other
position.
Programme the flexible button. Refer to
"1.20.2 Flexible Buttons" in the Feature
Guide.
Make sure that the cable is connected
properly with correct pin assignments.
Also, make sure that the cable does not
make short circuits.
Switch all DIP switches off.
Change the port status from Out of
Service to In Service using the
Maintenance Console.
Upgrade the LPR software of the DHLC/
DLC card.

Advertisement