EB-1 Electrical Box

The fireplace, when installed, must be electri-
cally connected and grounded in accordance
with local codes or, in the absence of local
codes, with the current CSA C22.1 Canadian
Electrical Code.
For USA installations follow local codes and
the national electrical code ANSI/NFPA No.
70.
It is strongly suggested that the wiring of the
EB-1 Electrical Junction Box be carried out
by a licensed electrician.
Ensure that the power to the supply line has
been disconnected before commencing this
procedure.
The EB-1 Electrical junction box has been fitted standard
on this model to allow for the easy connection of an op-
tional fan kit.
To connect the EB-1 box to the house electrical supply
follow the steps below.
1. Unscrew the retaining screw from the EB-1 base plate
and remove the EB-1 assembly from the
ance. (Fig. 8)
. Remove the front cover of the EB-1 box.
3. Remove the plug socket assembly from the EB-1 box.
4. Feed the supply line in through the EB-1 opening in the
side of the appliance and then through the back of the
EB-1 assembly. (Fig. 8)
5. Connect the black wire of the power supply line to the
brass screw (polarized) of the socket assembly.
6. Connect the white wire of the power line to the chrome
screw of the socket assembly.
7. Connect the ground wire of the supply line to the green
screw of the socket assembly.
8. Refit the socket assembly back into the electrical box
and replace the cover plate. Secure the cable with the
clamp on the outside of the EB-1 base plate and refit
the EB-1 assembly to the unit with the screw removed
in step 1.
10007317
Fig. 8 EB-1 receptacle.

Electronic Gas Control Valve

This appliance may be fitted with a Synetek ignition
module.
Installation of the remote on/off starter switch or wall
thermostat on electronic ignition units.
1. Thread the wiring through the holes on the side panels
of the appliance. Take care not to cut the wire or insula-
tion on metal edges. Route the wire to a conveniently
located receptacle box.
a p p l i -
. Attach the wire to the ON/OFF switch and install the
switch into the receptacle box.
3. Connect the white wire from the wall switch or wall
thermostat to the white wire terminal from the electronic
module. Connect the black wire from the wall switch or
the red wire from the wall thermostat, to the red wire
terminal from the electronic module.
LDVR Series Direct Vent Gas Fireplace
INSIDE
Electrical Box
Retaining Screw
OUTSIDE
FP580
INSTA VENT FREE
EB1 JUNCTION BOX
11/18/97
FP580
9