Always check for gas leaks with a mild
soap and water solution applied with a
brush no larger than 1" (25mm). Never
apply soap and water solution with a
spray bottle. Do not use an open flame
for leak testing.
The fireplace valve must not be sub-
jected to any test pressures exceeding
1/2 psi. Isolate or disconnect this or any
other gas appliance control from the gas
line when pressure testing.
The gas control is equipped with a captured screw type
pressure test point, therefore it is not necessary to
provide a 1/8" test point up stream of the control.
When using copper or flex connector use only ap-
proved fittings. Always provide a union when using
black iron pipe so the gas line can be easily discon-
nected for burner or fan servicing. (Fig. 4) See gas
specification for pressure details and ratings.

Remote Switch Installation

Do not wire remote "ON/OFF" wall switch
for this gas appliance into a 120v power
supply.
1. Thread wire through the electrical knockout located
on either side of fireplace. Do not cut wire or insula-
tion on metal edges. Ensure that wire is protected.
Run the other end to a conveniently located wall
receptacle box.
2. Attach wire to switch and install switch into recepta-
cle box. Attach cover plate to switch.
3. Connect wiring to gas valve. (Fig. 5)
Thermopile
Switch
Fig. 5 Remote switch wiring diagram for R models.
20003565
Vermont Castings Majestic Products NV360/580 Series
T
access door. Simply mount the switch to the switch
bracket provided. Screw the bracket on either side of
the frame, lining up the screws with the prepunched
holes. (Fig. 6)
Fig. 6 Alternate switch location.
The EB-1 electrical junction box has been supplied
standard on the NV360/580 models to allow for the
easy installation of an optional fan kit.
To connect the EB-1 box to the house electrical supply,
follow the steps below:
1. Unscrew the retaining screw from the EB-1 base
Gas Valve
W584-9
2. Remove the front cover of the EB-1 box.
3. Remove the plug socket assembly from the EB-1
4. Feed the supply line in from the outside through the
5. Connect black wire of the power supply line to the

Alternate Switch Location

he remote switch can be installed on either side of the

EB-1 Electrical Box

The fireplace, when installed, must be
electrically connected and grounded in
accordance with local codes or, in the
absence of local codes, with the current
CSA C22.1 Canadian Electrical Code.
For USA installations, follow local codes
and the National Electrical Code, ANSI/
NFPA No. 70.
It is strongly suggested that the wiring of
the EB-1 electrical junction box be
carried out by a licensed electrician.
Ensure that the power to the supply line
has been disconnected before commenc-
ing this procedure.
plate (Fig. 7) and remove the EB-1 assembly from
the fireplace.
box.
cable clamp. (Fig. 7)
brass screw (polarized) of the socket assembly.
FP1024