Installation Preparation; Cleaning; Flue Damper; Gas Line - Majestic MDVI30IN Installation Manual

Ruby series
Hide thumbs Also See for MDVI30IN:
Table of Contents

Advertisement

6 6

Installation Preparation

Prepare the existing solid fuel masonry or factory built
non-combustible fi rebox for installation.
A. Cleaning
Prior to installing the gas insert:
• Ensure that the woodburning fi replace cavity is clean
and free of ash, soot, and other debris.
B. Flue Damper
Fully lock the solid fuel fi replace's fl ue damper in the open
position, OR completely remove it.
C. Gas Line
Note: If the factory built fi replace has no gas access hole
provided, an access hole of 1 inch (25 mm) diameter or
less may be drilled through the lower sides or bottom of the
fi rebox in a proper workmanship - like manner. This access
hole must be plugged with non-combustible insulation after
the gas supply line has been installed.
• Install gas line into fi rebox cavity.
• Check local codes and gas line sizing requirements
following NFPA51. See Section 9.
• It is recommended that extra length of gas line be
installed within the existing wood burner or masonry
fi replace to allow removal of the insert for future servicing
needs.
12
Majestic • MDVI30IN, MDVI35IN, MDVI30IL, MDVI35IL Installation Manual • 2205-980 Rev. H • 12/16
D. Fireplace Conversion Notice
Permanently attach the label with the following warning to
the inside lower back of the fi replace fi rebox into which the
insert is being installed. Silicone or mechanical fasteners
may be required to properly secure the label.
WARNING! Risk of Fire! This fi replace has been con-
verted for use with a gas fi replace insert only and cannot
be used for burning wood or solid fuels unless all original
parts have been replaced, and the fi replace re-approved
by the authority having jurisdiction.
E. Electrical Outlet Box
An outlet box may be installed in a bottom back corner of
the existing solid fuel masonry or factory built fi replace
to power the appliance. Each unit ships standard with a
cord assembly to permit blowers or other optional acces-
sories to be used. The accessories plug into the new out-
let box or may be routed out onto the hearth to a nearby
outlet.
F. Remote Control Confi guration
The Intellifi re
TM
Plus should be programmed to the RC200
remote control prior to the installation of the insert into the
existing solid fuel masonry or factory built fi replace.
The control is accessed by removing the lower access
panel behind the decorative front. Reference the specifi c
RC200 user instructions for confi guring the remote to the
appliance.