Mounting the RO module

Step 10
Determine the best location for the RO Module to be
mounted and allow for future system maintenance.
Use a Phillips screwdriver and secure the screws
5 3/4" apart and 16" from the bottom of the cabinet.
Note: There will be (2) Blue, (1) Green and (1) Black
coming from the module. Do not cut these tubes at
this time.
Connecting to the faucet
Step 11
Connect blue tube from in-line filter over to the faucet shank.
Place the brass nut onto the tube, followed by the plastic sleeve
(tapered end pointing to the end of tube) and then place the
brass insert into the end of the tube.
Step 12
Insert the blue tube into the end of the faucet shank and use a
wrench to tighten the brass nut securely.
Connect the hot and cold water supply line valves
Insert the Green tube into the Cold water needle valve fitting
Step 13
1/4" tube compression fitting until it stops. Slide the Nut and
Plastic Sleeve down to where you can thread them onto the
male pipe threads. Use a 1/2" wrench to securely tighten.
Step 14
Insert the Black tube into the Hot water needle valve fitting
1/4" tube compression fitting until it stops. Slide the Nut and
the Plastic Sleeve down to where you can thread them onto the
male pipe threads. Use a 1/2" wrench to securely tighten.