In the following drawing, the steps to achieve this combination are explained.
① The exposure control is the same as in continuous mode.
② When the trigger signal is input, the charge that has already been accumulated during the
current exposure period is read out very quickly and a new exposure period starts. The
exposure continues as in continuous mode.
③ All video level data from every exposure is transferred to ALC control.
④ The video output sent to the GigE interface is only the signal after the trigger is input.
Trigger IN
Sensor Gate
(Normal Exposure
operation)
Exposure
Video Out used
for ALC control
ALC control
Signal
Video Output
8.8

Sequence Mode

8.8.1

Sequence mode setting

This is a function to capture images in sequence based on preset ROI, Exposure Time, Gain and other
parameters in the sequence index table. To use sequence mode, Video Send Mode must be set to
"Command Sequence." In the GO-5000-PMCL, this is the only command sequence mode available.
Video Send Mode
Command Sequence
Basic setting to use this function
Trigger Mode: ON
Exposure mode : Timed
Video Send Mode: Command Sequence
Table – 29
Minimum trigger interval (1x8–1Y)
Trigger Mode
Readout Mode
Full
ROI Center 2/3
Sequence
ROI Center 1/2
mode
ROI Center 1/4
ROI Center 1/8
V Binning ON (Full)
(Note 1)
Fig.22 RCT mode timing for ALC operation (Example)
Select the index directly by setting the index number with the Command
Sequence Index command.
9435 us + Exposure time + 8.01µs
6281 us + Exposure time + 8.01µs
4740 us + Exposure time + 8.01µs
2393 us + Exposure time + 8.01µs
1219 us
4740 us + Exposure time + 8.01µs
How to select Index
Time (Min. Trigger Period)
+ Exposure time + 8.01µs
- 49 -