Video Send Mode; Sequence Mode - JAI GO-5000M-PGE User Manual

Jai go-5000m-pge; go-5000c-pge 5m digital progressive scan monochrome and color camera
Hide thumbs Also See for GO-5000M-PGE:
Table of Contents

Advertisement

Primary settings to use this mode
Exposure Mode: Timed
Trigger Selector: Frame Start
Trigger Mode: ON
Trigger Option: RCT
If ALC control is used together with RCT mode, then
Exposure auto: Continuous
Gain Auto: Continuous
Minimum interval of the trigger
Read out mode
Full
ROI 2/3 (Height=1365)
ROI 1/2 (Height=1024)
ROI 1/4 (Height=512)
ROI 1/8 (Height=256)
1/2V Binning (Note 1)
Note1: GO-5000M-PGE only
8.8

Video Send Mode

The GO-5000-PGE has a Video Send Mode and it includes the following operations.
Table-24 Video send mode
Mode selected
Normal
Multi ROI
Trigger Sequence
Command Sequence
Delayed Readout
8.8.1

Sequence Mode

This mode allows the user to define a preset sequence of up to 10 images, each with its own ROI,
exposure time and gain values. This mode has two operation modes.
Mode selected
Trigger Sequence
Command Sequence
Primary settings to use this mode
Exposure Mode: Timed
Trigger Mode: ON
Video Send Mode: Trigger Sequence or Command Sequence
GO-5000M-PGE / GO-5000C-PGE
Minimum trigger interval
45.2 ms + Exposure time + 271 µs
30 ms + Exposure time + 271 µs
22.4 ms + Exposure time + 271 µs
11.4 ms + Exposure time + 271 µs
5.8 ms + Exposure time + 271 µs
22.4 ms + Exposure time + 271 µs
Index selection method
Normal operation
Up to 5 ROI images can be set up. Each image is output
independently.
Up to 10 indexes can be set for ROI, Exposure Time and Gain.
Select the index by using the Frame Start trigger signal.
Up to 10 indexes can be set for ROI, Exposure time and Gain.
Select the index number to assign directly by using the
Command Sequence Index command.
Up to 7 frames can be stored (8-bit). Each image can be
output by Acquisition Transfer Start trigger timing.
Index selection method
Select the index by using the Frame Start trigger signal. (The
setting index can be determined by the Next Index setting.)
Select the index number to assign directly by using the
Command Sequence Index command.
- 46 -

Advertisement

Table of Contents
loading

This manual is also suitable for:

Go-5000c-pge

Table of Contents