Input And Output Matrix Table; Pulse Generator - JAI GO-5000M-PMCL User Manual

5m cmos digital progressive scan monochrome and color camera
Hide thumbs Also See for GO-5000M-PMCL:
Table of Contents

Advertisement

6.3.7.2

Input and output matrix table

The relationship between input and output is as follows.
Table-7
GPIO matrix table
Selector (Cross
point switch output)
Source signal
(Cross point switch input)
Low
High
Soft Trigger
Exposure Active
Frame Trigger Wait
Frame Active
FVAL
LVAL

Pulse Generator 0

CL CC1 in
NAND 0 Out
NAND 1 Out 1
6.4
Pulse Generator
The GO-5000-PMCL has a frequency divider using the sensor clock as the basic clock and one pulse
generator. In the Pulse Generator, various Clear settings are connected to GPIO.
The following shows the Pulse Generator default settings. In the GO-5000-PMCL, the sensor pixel clock
is 36 MHz for 8-bit, 28.8MHZ for 10-bit and 24 MHZ for 12-bit.
Table - 8
Pulse Generator default settings
Display Name
Clock Pre-scaler
Pulse Generator
Selector
-
Pulse Generator 0
Note:]
When Pulse Generator Repeat Count is set to "0", the camera is operating in free-running mode.
However, based on the above default settings, Length=1, Start Point=0 and End Point=1, Pulse Generator
stops at High output. Therefore, if Start Point=0 and End Point=1 are configured, Length should be "2"
as the minimum active width.
GO-5000M-PMCL / GO-5000C-PMCL
Trigger Selector
Trigger Source
Value
1
Pulse Generator
Length
Start
End
Point
Point
1
0
1
Line Selector
Repeat
Clear
Clear
Count
Source
Inverter
0
Off
- 20 -
Pulse Generator
Selector
Pulse Generator
Clear Source
Clear
Clear
Activation
Sync
Mode
Async
True
Off
Mode