8.7.
RCT mode
8.7.1
RCT mode
Until the trigger is input, the camera operates continuously and can use auto-gain, if necessary, to
control the exposure setting. During this time, FVAL and LVAL are output but DVAL is not output. When
the trigger is input, the fast dump is activated to read out the electronic charge very quickly, after which
the accumulation and the readout are performed. When the accumulated signal against the trigger is
read out, FVAL, LVAL and DVAL are output too.
Primary settings to use this mode
Trigger Mode = ON
Exposure Mode = Timed
Trigger Option = RC
Table – 28
Minimum trigger interval (1X8–1Y)
Trigger Mode
Reset Continuous
Trigger Mode
(Note2)
Note1: GO-5000M-PMCL only
Trigger
CMOS
Exposure
Exposure
Active
FVAL
DVAL
8.7.2
RCT mode together with ALC function
RCT mode can use ALC control to ensure that the proper exposure is set when the trigger pulse is input.
In this case, the following settings are additionally required to RCT mode settings.
1. Exposure Auto: Continuous
2. Gain Auto: Continuous
GO-5000M-PMCL / GO-5000C-PMCL
Readout Mode
Full
AOI Center 2/3
AOI Center 1/2
AOI Center 1/4
AOI Center 1/8
V Binning ON (Full)
(Note1)
t1
28L
Fig.21
RCT mode timing
Time (Min. Trigger Period)
9435 us + Exposure time + 1.562 ms
6281 us + Exposure time + 1.562 ms
4740 us+ Exposure time + 1.562 ms
2393 us + Exposure time + 1.562 ms
1219 us + Exposure time + 1.562 ms
4740 us + Exposure time + 1.562 ms
t1
t2
9L ~10L
- 48 -
t2