Interface Connections; Model 1260 - Qualstar 1260 User Manual

Table of Contents

Advertisement

1-4
Fanlnleffi
UW
Power
'\~
Switch
roolU
~II
AC Plug and
Fuseholder
1260
Without Door Option
With Door Option
Additional for SCSI or
buffer option
o
WIDTH
- I
WIDTH
HEIGHT
12.25 inches 21.50 inches
(31.1 cm)
(54.6 cm)
12.75 inches 21.50 inches
(32.4 cm)
(54.6 em)
none
none
Figure 1-3
1260 Dimensions
~nT
~
I
1
I
I
I
HEIGHT
II~~
- I
DEPTH
1-
DEPTH
WEIGHT
8.25 inches
38 pounds
(20.9 cm)
(17.2 kg)
9.25 inches
44 pounds
(23.5 cm)
(19.9 kg)
1 inch
2 pounds
(2.5 cm)
1.8
Interface Connections
1.8.1
Model 1260
Note:
Model 1260 uses the Pertec interface which consists of either two cables with a 50-pin
card edge connector on each, or a single cable branching out into two 50-pin card edge
connectors. The card edge connectors must be connected to Jl and J2 (sometimes re-
ferred to as JI0l and JI02 respectively) inside of the tape drive.
A removable cable entry cover is attached to the side chassis panel with two Phillips
screws. A round interface cable can be fed through the slot in the cover. A decal shows
the correct connector orientation of Jl and J2.
1. Turn the tape drive offbefore attaching the interface cables.
2. With the drive resting on its rubber feet, remove the cable entry cover.
3. Connect the cables to Jl and J2 as shown on the decal.
4. Dress the cables and reinstall the cable entry cover.
The cable entry cover must
be
in place to meet FCC requirements.
Tape Drive Installation
500250 K