Rayburn 200SFW Installation Instructions Manual

Rayburn 200SFW Installation Instructions Manual

Solid fuel cooker
Hide thumbs Also See for 200SFW:

Advertisement

Consumer Protection
As responsible manufacturers we take care to make sure that our
products are designed and constructed to meet the required safety
standard when properly installed and used.
IMPORTANT NOTICE: PLEASE READ THE ACCOMPANYING
WARRANTY. Any alteration that is not approved by AGA could
invalidate the approval of the appliance, operation of the warranty
and could affect your statutory rights.
All local regulations including those referring to National and
European standards need to be complied with when installing
the appliance.
Important
This appliance may contain some of the materials that are
indicated. It is the Users/Installers responsibility to ensure that the
necessary personal protective clothing is worn when handling,
PERFORMANCE
REMEMBER, when replacing a part on this
appliance, use only spare parts that you can be
assured conform to the safety and performance
specification that we require. Do not use
reconditioned or copy parts that have not been
authorised by AGA.
The Rayburn 200SFW is intended to be used for
cooking only. The Rayburn 212SFW is intended to
supply heating for cooking and domestic hot water.
The Rayburn 200SFW has been tested using Ancit and
wood logs. The nominal heat output of this appliance is
Ancit 7.1 kW and wood logs 5.8 kW.
The Rayburn 212SFW has been tested using Ancit and
wood logs. The nominal heat output of this appliance is
Ancit 6.8 kW and wood logs 6.5 kW.
Ancit provides about 2.6 kW to hot water and 4.3 kW to
the appliance. Wood provides about 2.0 kW to hot
water and 4.5 kW to the appliance. Other fuels may
give a slightly different result.
Weight of Rayburn 212SFW - 300 Kgs.
Weight of Rayburn 200SFW - 240 Kgs.
There is no requirement for an electrical power supply.
Flue gas mass flow g/s 5.3.
The mean flue gas temperature of the Rayburn
200SFW directly downstream of the flue spigot at
nominal heat output is 200ºC.
Installation Instructions for
Rayburn 200SFW and Rayburn
212SFW Solid Fuel Cooker
where applicable, the pertinent parts that contain any of the listed
materials that could be interpreted as being injurious to health and
safety, see below for information.
Firebricks, Fuel beds, Artificial Fuels - when handling use
disposable gloves.
Fire Cement - when handling use disposable gloves.
Glues and Sealants - exercise caution - if these are still in liquid
form use face mask and disposable gloves.
Glass Yarn, Mineral Wool, Insulation Pads, Kerosene/Gas Oil -
may be harmful if inhaled, may be irritating to skin, eyes, nose and
throat. When handling avoid inhaling and contact with skin or
eyes. Use disposable gloves, face-masks and eye protection.
After handling wash hands and other exposed parts. When
disposing of the product, reduce dust with water spray, ensure that
parts are securely wrapped.
THE ASHPIT DOOR AND FIREBOX DOORS MUST
BE LOCKED CLOSED AT ALL TIMES DURING
NORMAL USE, EXCEPT WHEN LIGHTING OR RE-
FLUE GAS MASS FLOW
FUEL
WOOD
ANCIT
WOOD
ANCIT
The mean flue gas temperature of the Rayburn
212SFW directly downstream of the flue spigot at
nominal heat output is 203ºC.
The cooker fully meets the requirements of BS EN
12815 : 2001 and A1: 2004 and is fully approved by the
HETAS Ltd Approval Scheme.
Air for combustion within the firebox and the rate of
burning is determined by the manually operated
spinwheel control on the ashpit door and flue damper.
With normal usage in 24 hours continuous burning the
Rayburn 212SFW has an approximate output of 100
gallons of hot water. To provide 2 or 3 hot baths at
intervals and normal household requirements, the
following conditions must be fulfilled:-
1
WARNING
FUELLING
MODEL
200
5.3 g/s
200
5.6 g/s
212
5.9 g/s
212
5.9 g/s
02/15 EINS 514406
MEAN FLUE
GAS TEMP.
199°C
196°C
203°C
207°C

Advertisement

Table of Contents
loading

Summary of Contents for Rayburn 200SFW

  • Page 1 GAS TEMP. FUEL MODEL authorised by AGA. WOOD 5.3 g/s 199°C The Rayburn 200SFW is intended to be used for ANCIT 5.6 g/s 196°C cooking only. The Rayburn 212SFW is intended to supply heating for cooking and domestic hot water. WOOD 5.9 g/s...
  • Page 2: Electrical Connections

    A towel rail of not more than 0.5m heating surface may Rayburn 212SFW - It is recommended that a 140 litre be heated providing the flow and return pipes are not (30 galls) indirect hot water storage cylinder of the more than 5m each in length, and provided the cylinder double feed type, (e.g.
  • Page 3: Cooker Position

    Lift the insulating lids to prevent staining the linings. Rayburn 212SFW - Unscrew the sheet metal cover plate on the side of the cooker and remove the insulating material from behind it.
  • Page 4 THE CHIMNEY The minimum chimney draught requirement for the 200SFW at nominal total heat output is 12 Pa. The minimum chimney draught requirement for the 212SFW at nominal total heat output is 12 Pa. The mean flue gas temperature of the Rayburn 200SFW directly downwards of the flue spigot at nominal heat output is 200°C.
  • Page 5: Cooker Flue Connection

    The minimum diameter for a straight chimney is 150mm FLUE LAYOUTS and there should not be more than two bends of 45° from vertical. In Fig. 2 the cooker is installed in an existing recess. There must be a clearance of not less than 150mm IN ALL TYPES OF CHIMNEYS THE MINIMUM between the top of the flue pipe and any overhanging HEIGHT FOR CORRECT OPERATION OF THE...
  • Page 6: High Updraughts

    HIGH UPDRAUGHTS Tall chimneys may develop excessively high updraughts which prevent the appliance operating correctly. It is recommended that a proprietary brand adjustable flue draught stabiliser having an openable cross sectional area of 126cm be fitted above the flue pipe connection either in the brickwork or into a right angle ‘T’...
  • Page 7: Testing And Commissioning

    NOTE: The water capacity of the boiler is 7 litres FIREBRICK REPLACEMENT The firebricks fitted to the Rayburn Cookers are of first quality manufacture, and providing the cooker has been installed and used correctly will have a reasonable life.
  • Page 8 With AGA Rangemaster’s policy of continuous product improvement, the Company reserves the right to change specifications and make modifications to the appliance described at any time. Manufactured by AGA Rangemaster Station Road Ketley Telford Shropshire TF1 5AQ England www.rayburn-web.co.uk www.agacookshop.co.uk...
  • Page 9 LOCKED CLOSED AT ALL TIMES DURING NORMAL USE, EXCEPT WHEN LIGHTING OR RE-FUELLING The Rayburn 200SFW has been designed to burn a variety of solid fuels and thereby provide heating facilities The Rayburn 200SFW and Rayburn 212SFW has been for cooking.
  • Page 10: Door Operation

    Wet kitchen refuse should not be burned and the appliance should not be used as an incinerator. Rayburn 200SFW and 212SFW: Provision must be made for additional ventilation. A permanent unobstructed air vent having a minimum effective area of 11 cm...
  • Page 11 LIGHTING THE FIRE - USING WOOD AND PAPER 1. Check the flue pipe is free of blockage. 2. Open firebox door. 3. Open ashpit door. 4. Remove ashpan. 5. De-ash (Fig. 3) also see page 3 De-ashing and remove any dead fuel from bottomgrate as described under ‘Removal of Clinker and Bottomgrate’.
  • Page 12: Overnight Burning

    Control Setting REFUELLING Set spinwheel open which does not require to be open more than: 1. Coke - Five complete turns. Open the flue damper fully before opening the firebox 2. Other recommended fuels - three complete turns door. This will prevent smoke spilling into the room. during cooking period.
  • Page 13 (See Fig. 6A). Secondary Air Adjustment - Rayburn 212SFW Only When converting from solid fuel to wood burning, the secondary air calibration will require changing from a 6 aeration hole plate to a 8 hole plate, (See Fig.
  • Page 14: Warming Oven

    To reduce top heat in the oven, place the solid plain shelf USE OF THE HOTPLATE on the top or second pair of oven runners. The oven may be cleaned with a stiff wire brush, when it is very hot. WARNING: HOT SURFACES, use the tool supplied to Setting Oven Temperature...
  • Page 15: Chimney Fires

    Use a wire creosote (or more) coats the inner walls of the chimney. brush to keep the cast iron hotplate clean. General cleaning is best carried out when the Rayburn is cool. Prevention Chimney fires do not occur in clean, intact properly IMPORTANT NOTE: AGA recommend Vitreous Enamel installed chimneys.
  • Page 16 FIREBRICK REPLACEMENT in the same room as the appliance. If the alarm sounds unexpectedly, follow the instructions given under The firebricks fitted to the Rayburn 212SFW are of first “Warning Note” above. quality manufacture, and providing the cooker has been installed and used correctly will have a reasonable life.
  • Page 17: Cooking Hints

    As you have probably realised, the meat tray supplied with your Rayburn fits the oven, hanging directly from the runners, so leaving the grid shelves free for other dishes. The oven grid shelves are designed to be non-tilt and...
  • Page 20 With AGA Rangemaster’s policy of continuous product improvement, the Company reserves the right to change specifications and make modifications to the appliance described at any time. Manufactured by AGA Rangemaster Station Road Ketley Telford Shropshire TF1 5AQ England www.rayburn-web.co.uk www.agacookshop.co.uk www.agalinks.com...

This manual is also suitable for:

212sfw

Table of Contents