Ventilation Of Rooms; Gas Connection; Installation Instructions - Baumatic FG65 User And Installation Instructions Manual

Table of Contents

Advertisement

INSTALLATION INSTRUCTIONS

VENTILATION OF ROOMS

The room in which this appliance is installed must be well ventilated by natural or
mechanical means, or a combination of both to ensure correct combustion and the removal
of spent air.
The minimum quantity of air for combustion will depend on the room volume, number of
appliances and their total power rating.
The power rating of your appliance can be found by reference to the Rating Plate.
Note: The actual ventilation requirements must be determined by reference to the Statutory
Regulations in force.

GAS CONNECTION

The gas supply must be connected by use of the ½ BSP Elbow, seal and copper pipe and
an isolation tap fitted in an easily accessible position.
The appliance as supplied is for use with Natural Gas, if it is to be adapted for LPG
proceed as follows:
Isolate the appliance from the electricity and gas supplies.
Remove the pan supports and burner assemblies.
Replace the injectors with the alternative type supplied.
Use the appropriate thread sealant and check for gas soundness.
Affix the self-adhesive label to the Rating Plate to amend the Gas Category.
10
Fig. 2
Fig. 3