Ventilation Requirements - Baumatic B47SS Instruction Manual

4 burner gas hob and 4 burner gas hob with thermocouples
Hide thumbs Also See for B47SS:
Table of Contents

Advertisement

Ventilation requirements

o The room containing the cooker should have an air supply in
o The room must have opening windows or equivalent; some
o If the room has a volume between 5 and 10m³, it will require an
o If the room has a volume of less than 5m³, it will require an air
o If it is installed in a room with a volume that exceeds 11m³, then
o If there are any other fuel burning appliances in the same room
o Ensure that the room containing the cooker is well ventilated,
o Prolonged intensive use of the appliance may call for additional
o This hob is not fitted with a device for discharging the products
o The walls behind and near the hob should be resistant to heat,
o Remember that the quantity of air necessary for combustion
Get user manuals:
See SafeManuals.com
accordance with the current edition of BS 5440: Part 2:
rooms may also require a permanent vent.
air vent of 50cm² (effective area). Unless it has a door which
opens directly to the outside.
vent of 100cm² (effective area).
no air vent is required.
the current edition of BS 5440: Part 2: should be consulted to
determine air vent requirements.
keep natural ventilation holes or install a mechanical ventilation
device (mechanical cooker hood).
ventilation, either by the opening of a window, or by increasing
the level of the mechanical ventilation device (where present).
of combustion. Ensure that the ventilation rules and regulations
are followed.
steam and condensation.
must never be less than 2m³/h for each kW of power (see total
power in kW on the appliance rating plate).
18