stylus does not
properly aligned.
match the position
on the LCD.
Message appears
Too many files stored
that memory is
in the H-32.
full.
H-32 reboots after
Backup battery
main battery hot
condition too low.
swap.
Hot swap of main
battery too slow.
H-32 cannot scan
Unreadable barcode.
barcode.
H-32 barcode type not
enabled.
H-32 is out of scanning
range or at a wrong
angle.
H-32 does not give
user feedback that
barcode is scanned.
H-32 Optical Scan
Window is dirty.
H-32 keeps
Power pushed into the
rebooting
H-32 housing.
H-32 does not
One of the keypad
boot red key
keys has been pushed
message in
under the housing.
display.
H-32 shows
Keypad keys [*] + [6]
Factory Reset!!
have been pressed
During boot.
during boot.
H-32 shows Write
Keypad key [3]
OS to NAND
pressed during boot.
during boot.
Keypad key [3] stuck
under H-32 housing.
H32 User Guide
Stylus, Calibration tab and click the recalibrate button.
Follow instructions on the LCD. If needed the calibration
can be reached by operating the keypad only. Use FN + = for
horizontal tab.
Remove unneeded files.
Make sure that backup battery switch in the battery
compartment is set to the ON position and that it has at least
been charged for 24 hours.
The backup battery can hold the charge for a very short
time. Perform a quick main battery swap. When backup
battery has been used for a swap it needs time to get to an
acceptable level again.
Barcode damaged, defaced or out of specification.
Enable the barcode type from the scanner manager applet.
Change reading distance and angle. Check the chapter
Scanning considerations.
Set the Good read notification from the Scanner Manager
applet.
Clean the H-32 Optical Scan Window
Carefully use the stylus to get the power button in the
correct position. Power button was pushed in with the
stylus or other sharp object, only use fingers to operate
buttons and keys.
Carefully use the styles to get the stuck key to the correct
position. The keypad key was pushed in with the stylus or
other sharp object, only use fingers to operate buttons and
keys. To find out what key is stuck see keypad table below.
Normal operation.
Normal operation. Follow update procedure or reboot H-32
Carefully use the stylus to get the stuck [3] key to the correct
position. The keypad key was pushed in with the stylus or
other sharp object, only use fingers to operate buttons and
keys.
Troubleshooting the H32
46